𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Focused ultrasound solid–liquid extraction and selective pressurised liquid extraction to determine bisphenol A and alkylphenols in sewage sludge by gas chromatography–mass spectrometry

✍ Scribed by María P. Martínez-Moral; María T. Tena


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
305 KB
Volume
34
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A new method for determining endocrine disrupter compounds (EDCs) in sewage sludge is described in this paper. EDCs studied were bisphenol A (BPA) and alkylphenols (APs). In order to obtain a fast and simple method, selective pressurised liquid extraction (SPLE) and focused ultrasound solid–liquid extraction (FUSLE) were tested. Best results for SPLE were obtained using Florisil as clean‐up sorbent and dichloromethane as extraction solvent, while temperature was the only significant variable. Analyte extraction by SPLE was completed in only one extraction cycle of 1 min at 130°C. FUSLE was carried out in one step of 20 s at 75% power (0.5 cycles) and with 8 mL of ethyl acetate. Although the optimised FUSLE process was faster, simpler and cheaper, SPLE provided higher recovery values (ranging from 81 to 105%) and therefore SPLE‐based method was selected and validated. The SPLE and GC‐MS method showed an LOD of 10.7 ng/g for BPA and LODs between 1.2 and 41.6 ng/g for APs. Relative standard deviation values lower than 6% were obtained for all analytes. As a result, an efficient, fast and simple method based on SPLE and GC‐MS for the determination of BPA and APs in sewage sludge is proposed.


📜 SIMILAR VOLUMES


Highly sensitive determination of tetrab
✍ Ru-Song Zhao; Xia Wang; Jin-Peng Yuan 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 175 KB

## Abstract Using bamboo‐activated charcoal as SPE adsorbent, a novel SPE method was developed for the sensitive determination of tetrabromobisphenol A and bisphenol A in environmental water samples by rapid‐resolution LC‐ESI‐MS/MS. Important parameters influencing extraction efficiency, including

Validation and application of a method f
✍ David L. Heavner; Joel D. Richardson; Walter T. Morgan; Michael W. Ogden 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 292 KB 👁 1 views

An SPE-LC-MS/MS method was developed, validated and applied to the determination of nicotine and five major metabolites in human urine: cotinine, trans-3'-hydroxycotinine, nicotine-N-glucuronide, cotinine-N-glucuronide and trans-3'-hydroxycotinine-O-glucuronide. A 500 microL urine sample was pH-adju

Determination of phenolic compounds in e
✍ Hakim Faraji; Syed W. Husain; Masoumeh Helalizadeh 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 221 KB 👁 1 views

## Abstract A novel approach for the sample pre‐treatment and determination of eight phenolic compounds in environmental water samples has been developed by hyphenating solid‐phase extraction (SPE) and liquid‐phase microextraction (LPME) techniques based on solid organic drop combined with gas chro