## Abstract A novel flow‐injection method with chemiluminescence detection was developed for the determination of streptomycin residues in milk, based on the enhancement by streptomycin of the luminol–potassium periodate–Mn^2+^ chemiluminescence system. The assay allowed analysis of streptomycin re
Flow injection chemiluminescence determination of isoniazid using the lucigenin–periodate system
✍ Scribed by Jianxiu Du; Jiuru Lu
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 158 KB
- Volume
- 21
- Category
- Article
- ISSN
- 1522-7235
- DOI
- 10.1002/bio.878
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A weak chemiluminescence (CL) signal was observed during the mixing of isoniazid with lucigenin in alkaline aqueous solution. The CL signal was enhanced more than 100 times in the presence of potassium periodate. This CL system was developed for the determination of isoniazid using a flow injection mode. The CL intensity is proportional to the concentration of isoniazid in the range 0.005–1.0 mg/L. The limit of detection is 0.0034 mg/L and the relative standard deviation is 2.0% for 0.2 mg/L isoniazid solution in 11 repeated measurements. The method was applied to the determination of isoniazid in pharmaceutical preparations and satisfactory results were obtained. Copyright © 2005 John Wiley & Sons, Ltd.