𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Flow cytometry for assessing biocompatibility

✍ Scribed by Lopes, M. A. ;Knowles, J. C. ;Kuru, L. ;Santos, J. D. ;Monteiro, F. J. ;Olsen, I.


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
362 KB
Volume
41
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


Flow cytometry (FCM) was examined as a possible procedure for measuring in vitro the biocompatibility of implant materials for orthopedic and dental surgery. The human osteoblast-like cell line MG63 was grown on hydroxyapatite (HA) and P2O5 glass-reinforced HA composite discs and compared with the same cells grown on polystyrene culture dishes. While morphological observation at the light and electron microscopic levels showed no major deleterious effects, FCM indicated that cell size was somewhat reduced, particularly by growth on the HA composite. Morever, this material also appeared to delay the progression of the cells from the G0/G1 into the S phase of the cell cycle. In addition to this low level of inhibition of cell growth relative to control cultures, FCM analysis also demonstrated that the glass-reinforced HA caused some down-regulation of the expression of osteocalcin and fibronectin, two antigens which play a vital part in the integrity and function of bone and soft connective tissue, respectively. These results thus show, first, that although HA and the HA composite used in these experiments were generally biocompatible, they nevertheless had certain suboptimal effects on the cells; and second, that FCM could be a highly useful procedure for effectively screening and evaluating important biological responses to implant materials.


πŸ“œ SIMILAR VOLUMES


Assessment of electroporation by flow cy
✍ J. Michie; D. Janssens; J. Cilliers; B.J. Smit; L. BΓΆhm πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 171 KB πŸ‘ 2 views
Flow cytometry and cell sorting for yeas
✍ Deere, Daniel; Shen, Jian; Vesey, Graham; Bell, Philip; Bissinger, Peter; Veal, πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 352 KB πŸ‘ 1 views

Yeast suspensions were analysed by flow cytometry after dye staining for determination of total and viable cell densities. Results were comparable to traditional colony counting and, in addition, provided further information on the percentage of total cells that were viable. The flow cytometric meth

Standardizing flow cytometry: A classifi
✍ A. Schwartz; G. E. Marti; R. Poon; J. W. Gratama; E. FernΓ‘ndez-Repollet πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 69 KB πŸ‘ 2 views

The growing number of standards commercially available in the field of flow cytometry makes it difficult to know which standards to use to obtain a desired level of quality assurance. A classification system of fluorescence standards has been developed on the basis of their physical characteristics.

Enrichment for submitotic cell populatio
✍ R.J. Widrow; Charles D. Laird πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 168 KB πŸ‘ 1 views

Background: One of the most dramatic events during the course of the mammalian cell cycle is mitosis, when chromosomes condense and segregate, the nuclear envelope breaks down, and the cell divides into two daughter cells. Although cells undergoing mitosis are cytologically distinguishable from nonm

Translesional flow velocity for lesion a
✍ Kern, Morton J. ;Donohue, Thomas J. ;Bach, Richard G. ;Caracciolo, Eugene ;Aguir πŸ“‚ Article πŸ“… 1993 πŸ› John Wiley and Sons 🌐 English βš– 119 KB