Clinical studies suggest that stent design and surface texture are responsible for differences in biocompatibility of metallic endovascular stents. A simple in vitro experimental setup was established to test stent-induced degree of platelet and leukocyte activation and platelet-leukocyte aggregatio
Flow cytometric assays to detect platelet activation and aggregation in device-implanted calves
β Scribed by Baker, Linda C. ;Davis, William C. ;Autieri, Jacqueline ;Watach, Mary J. ;Yamazaki, Kenji ;Litwak, Philip ;Wagner, William R.
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 263 KB
- Volume
- 41
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
Cardiovascular device development often relies upon large-animal models to assess blood biocompatibility prior to initiating clinical trials. Unfortunately, the amount of information gleaned from such trials is limited by simple assays that do not take full advantage of immunotechnological advances that increasingly are applied in clinical studies. Thus we have developed and tested new flow cytometric techniques for measuring circulating activated bovine platelets and platelet microaggregates. Monoclonal antibodies (MAbs) raised against both activated and quiescent bovine platelets were incubated with control and PMA-or ADP-stimulated whole blood. Selected MAbs detected activated bovine platelets and platelet microaggregates in vitro with flow cytometry. Five calves implanted with one of two designs of nonpulsatile ventricular-assist devices (VADs) were followed with these assays prior to and during VAD implantation. Circulating activated bovine platelets and microaggregates increased after implantation in all animals and, alternatively, remained elevated or returned toward preimplant levels. Platelet activation percentages as detected temporally by three MAbs were correlated with one another, and platelet activation was correlated with microaggregate formation. In summary, these new methods for the sensitive measurement of circulating activated bovine platelets and microaggregates may provide valuable information for the development and assessment of future cardiovascular device designs.
π SIMILAR VOLUMES
Two flow cytometric apoptosis assays, the terminal deoxynucleotidyl transferase (TdT) assay and in situ nick translation (ISNT) assay, were assessed for their ability to quantitate drug-induced apoptosis in CLL lymphocytes. In contrast to HL60 cells, biotinylated dUTP could not be effectively incorp