✦ Synopsis


Fluorescence in situ hybridization allows the enumeration of chromosomal abnormalities in interphase cell nuclei. This process is called dot counting. To estimate the distribution of chromosomes per cell, a large number of cells have to be analyzed, especially when the frequency of aberrant cells is low. Automation of dot counting is required because manual counting is tedious, fatiguing, and timeconsuming.

We developed a completely automated fluorescence microscope system that can examine 500 cells in approximately 15 min to determine the number of labeled chromosomes (seen as dots) in each cell nucleus. This system works with two fluorescent dyes, one for the DNA hybridization dots and one for the cell nucleus. After the stage has moved to a new field, the image is automatically focused, acquired by a Photometrics KAF 1400 camera (Photometrics Ltd., Tuscon, AZ, USA), and then analyzed on a Macintosh Quadra 840AV (Apple Computer, Inc., Cupertino, CA, USA) computer. After the required number of cells has been analyzed, the user may interact to correct the computer by working with a gallery of the cell images.

The automated dot counter has been tested on a number of normal specimens where 4,86-diamidino-2-phenylindole (DAPI) was used for the nucleus counterstain and a centromeric 8 probe was used to mark the desired chromosome. The slides contained lymphocytes from cultured blood. We compared the results of the dot counter with manual counting. Manually obtained results, published in the literature, were used as the ''ground truth.'' For a normal specimen, 97.5% of cells will have two dots. Fully automated scanning of 13 slides showed that an average of 89% of all nuclei were counted correctly. In other words, an average of 11% has to be interactively corrected, using a monitor display. The machine accuracies, after interactive correction, are comparable to panels of human experts (manual). The fully automatically obtained results are biased with respect to manual counting. An error analysis is given, and different causes are discussed. Cytometry 28:1-10, 1997.


📜 SIMILAR VOLUMES


Automated FISH spot counting in interpha
✍ Carlos Ortiz de Solórzano; Andrés Santos; Isabel Vallcorba; José-Miguel García-S 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 63 KB

The evaluation of an automated system for Fluorescence In Situ Hybridization (FISH) spot counting in interphase nuclei is presented in this paper. Different types of experiments have been performed with samples from known populations. In all of them the goal is to detect mosaicism of chromosome X in

High-resolution cytometry of FISH dots i
✍ M. Kozubek; S. Kozubek; E. Lukášová; A. Marec̆ková; E. Bártová; M. Skalníková; A 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 247 KB

Background: Flow cytometry (FCM) and laser scanning cytometry (LSCM) provide indispensable tools for measuring large number of cells with low resolution. Confocal microscopy, on the other hand, is used for measuring small number of cells with high resolution. In this paper, we present a reasonable c

Smart 3D-fish: Automation of distance an
✍ Michael Gué; Cédric Messaoudi; Jian Sheng Sun; Thomas Boudier 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 466 KB

## Abstract ## Background Detection of fluorescent probes by fluorescence in situ hybridization in cells with preserved three‐dimensional nuclear structures (3D‐FISH) is useful for studying the organization of chromatin and localization of genes in interphase nuclei. Fast and reliable measurements

Fluorescence in situ hybridization to in
✍ Barbara Trask; Ger Engh; Dan Pinkel; Jim Mullikin; Fred Waldman; Herman Dekken; 📂 Article 📅 1988 🏛 Springer 🌐 English ⚖ 1000 KB

Fluorescence hybridization to interphase nuclei in liquid suspension allows quantification of chromosome-specific DNA sequences using flow cytometry and the analysis of the three-dimensional positions of these sequences in the nucleus using fluorescence microscopy. The three-dimensional structure of