๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Fire safety assessment of wooden facades

โœ Scribed by Tuula Hakkarainen; Tuuli Oksanen


Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
379 KB
Volume
26
Category
Article
ISSN
0308-0501

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

The fire behaviour of wooden facades in multiโ€storey houses has been studied in a Nordic research project on the fire safety of timber framed buildings. Two different fire scenarios were considered: a relatively small ignition source outside the building and a postโ€flashover compartment fire. The scenarios correspond to potential fire situations in sprinklered and unsprinklered houses, respectively.

Fire tests of wooden facades with different cladding materials, surface treatments and structures were performed on intermediate and large scales. In the case of an external fire, the most efficient way to prevent the propagation of flames to the upper storeys of the facade is the structural modification of the facade profile, i.e. cantilevers and oriels. Particular care should be taken so that the protrusion is of sufficient depth and width and that its front and lower surfaces are nonโ€combustible. Using fire retardant treatment, the flame spread can be considerably delayed or even halted. Acceptance criteria for the facades of sprinklered and unsprinklered multiโ€storey buildings are suggested based on the test series. Similar principles can be applied when defining criteria for various test arrangements and fire scenarios. Copyright ยฉ 2002 John Wiley & Sons, Ltd.


๐Ÿ“œ SIMILAR VOLUMES


Quantified fire safety assessments
โœ Janet M. Murrell; J. R. Barnfield ๐Ÿ“‚ Article ๐Ÿ“… 1988 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 76 KB
Safety assessment of factory automation
โœ Yoshiyuki Mineo; Yoshihisa Suzuki; Tatsuya Niinomi; Katsumi Iwatani; Hisao Sekig ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 198 KB ๐Ÿ‘ 1 views

When accidents occurring in a factory automation (FA) system are analyzed, it is found that many of them cannot be expressed in terms of probability. They include accidents occurring when an interlock did not function as designed due to the dead angle in the object detection sensor, and those caused

Fire performance standards and the probl
โœ T. Z. Harmathy ๐Ÿ“‚ Article ๐Ÿ“… 1980 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 409 KB

## Abstract It is submitted that the development of a set of complementary performance test standards and of an algorithm for calculating from the test results the inherent potential of products for harm is the prerequisite of any progress towards a coherent fire risk assessment philosophy.

Safety assessment of high pressure treat
โœ Gerhard Eisenbrand ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 104 KB

The DFG-Senate Commission for Food Safety (SKLM) considered the high pressure treatment of foodstuffs already in 1998 and published an opinion entitled "High pressure treatment of foodstuffs, particularly fruit juices". In view of the continued development of this technology, the extension of the ty