Fire protection: Detection, notification, and suppression
â Scribed by Till R.C., Coon J.W
- Publisher
- Springer
- Year
- 2019
- Tongue
- English
- Leaves
- 217
- Edition
- 2
- Category
- Library
No coin nor oath required. For personal study only.
⌠Table of Contents
Dedication......Page 5
Preface......Page 6
A Word on Units......Page 7
Acknowledgments......Page 8
Contents......Page 9
Stages of Fire Growth......Page 18
Full Room Involvement......Page 20
Influence of Fire on Humans......Page 21
Calculation of Flashover......Page 22
Diagnostic Room Fires......Page 23
Office Building Design Fires: Examples......Page 24
Open Office Plans and Spreadover......Page 25
References......Page 27
Early Automatic Suppression Systems......Page 28
Skepticism......Page 29
The Influence of Frederick Grinnell......Page 30
Component: The Deflector......Page 31
Components: The Operating Element(s)......Page 32
K-Factor......Page 33
Development of the Large Orifice Head......Page 34
Dry Pendant Sprinklers......Page 35
Sidewall Sprinklers......Page 36
Decorative Sprinklers......Page 37
Special Heads......Page 38
Corrosion-Resistant Sprinklers......Page 39
CMDA (Standard Spray)......Page 40
Other Common Characteristics of Spray Sprinkler......Page 41
References......Page 42
Thermal Detection Systems......Page 43
Rate of Rise Detector......Page 45
Photoelectric Detector Operation......Page 47
Linear Beam Smoke Detector......Page 48
Rate Compensation Detector......Page 49
Flame Detectors......Page 50
Air Aspirating Smoke Detection Systems......Page 53
Fire Alarm......Page 55
911 System......Page 56
Addressable FACU......Page 57
Other Issues......Page 58
Remote Alarm......Page 59
References......Page 60
Fire Pumps......Page 61
General Criteria......Page 62
Pump Suction......Page 63
Suction and Discharge Piping......Page 64
Main Relief Valve......Page 65
Pump Test Design......Page 66
Engine Exhaust......Page 68
Diesel Engine Cooling System......Page 69
Jockey Pump Controller......Page 70
Controller Alarm and Signal Devices......Page 71
Weekly Diesel Drive Pump Test......Page 72
Fire Pump Field Acceptance Test......Page 73
Tank Selection......Page 75
Concrete Reservoir......Page 76
Summary......Page 77
Cast Iron Pipe......Page 78
Friction Loss: The âCâ Factor......Page 79
Asbestos Cement Pipe......Page 80
Rodding and Thrust Blocks......Page 81
Flushing and Testing......Page 82
The Post Indicator Valve (PIV)......Page 84
Butterfly Valve......Page 86
Detector Check Valves and Full Flow Fire Meters......Page 87
Backflow Preventers......Page 88
Established Burning to Arrival......Page 90
Arrival and Size Up......Page 91
Standpipes: Minimizing Set Up Time......Page 93
Class II Standpipe......Page 94
Pressure Requirements......Page 95
Class III Standpipe......Page 96
Types of Standpipes......Page 97
Hose Station Distribution......Page 98
Standpipe Zoning......Page 100
Set Up Time: Firefighting Tasks......Page 101
Size of a Fire that Can Be Extinguished......Page 102
References......Page 103
Wet Pipe Sprinkler System......Page 104
Water Damage......Page 106
Water Flow Indicator......Page 107
Alarm Valve......Page 109
Retard Chamber......Page 110
Alarm Valve Trim......Page 111
Fire Department Pumper Connection......Page 112
Main Control Valve......Page 113
Inspectorâs Test......Page 114
Wet Pipe System Drainage......Page 115
Dry Pipe Sprinkler System......Page 116
Advantages and Disadvantages of Dry Pipe Systems......Page 117
Low Differential Dry Pipe Valve......Page 118
Dry System Air Supply......Page 119
Optional Devices......Page 120
Accelerators......Page 121
Exhausters......Page 122
Drainage Capacities......Page 123
Calculating the Area of Application......Page 124
Water Columning......Page 125
Deluge Systems......Page 126
Pre-action Systems......Page 128
Detection System......Page 129
Use of Preaction Systems......Page 131
Pre-action System Design Features......Page 132
Double Interlock......Page 133
Water Spray System......Page 134
Controlled Burning......Page 135
Water Spray Versus Sprinkler Systems......Page 136
Nozzle Selection......Page 137
Water Supply......Page 138
References......Page 139
Design Criteria......Page 140
Flow Data......Page 141
Flow Test......Page 142
Computer Versus Hand Calculations......Page 144
Summary......Page 145
History: Foam Systems......Page 161
Use and Calculation of Foam......Page 162
Selecting Proportioning Systems and Devices......Page 163
Reserve Systems......Page 164
Detection Systems......Page 165
Water Supply......Page 166
High Expansion Foam Generators......Page 167
High Expansion Foam Uses......Page 168
Types of Foam â Properties Performance......Page 169
High Expansion Foam......Page 170
Carbon Dioxide Systems......Page 172
Grounding......Page 173
Re-Ignition......Page 174
Extended Discharge......Page 175
High Pressure Systems......Page 176
Maintenance Considerations for High Pressure......Page 177
How the System Works......Page 178
Discharge Nozzles......Page 179
The Storage Tank and Refrigeration......Page 180
Dual Purpose Carbon Dioxide Units......Page 181
Carbon Dioxide Hose Stations......Page 182
Rate-By-Area Method......Page 183
Rate-By-Volume Method......Page 185
Total Flooding System Design......Page 186
Clean Agents-Replacing Halon......Page 188
Global Warming Potential......Page 189
Halocarbon Agents......Page 190
Quantities of Clean Agents......Page 191
Need for Precise Design......Page 194
Rapid Discharge Rate......Page 195
Storage Conditions......Page 196
Partial Total Flooding Halon 1301 Systems......Page 197
Classification of Dry Chemicals......Page 198
Tests......Page 199
Dry Chemical Hand Hose Systems......Page 200
References......Page 201
National Fire Protection Association......Page 202
FM Global......Page 204
Building Codes......Page 205
New Versus Existing Buildings......Page 207
Fire Marshal and Fire Prevention Bureau......Page 208
Water Department......Page 209
Summary......Page 210
Construction Specification Standards......Page 211
Applicable Standards......Page 212
Design Criteria......Page 213
Acceptable Manufacturers......Page 214
Sprinkler Heads......Page 215
Reference......Page 217
đ SIMILAR VOLUMES
<br> Content: An overview of Halon 1301 systems / Charles L. Ford --<br/> The relevance of fundamental studies of flame inhibition to the development of standards for the halogenated extinguishing agent systems / Myron J. Miller --<br/> CFâBr suppression of turbulent, class-B fuel fires / Norman J.