𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Finite element analysis of the influence of the offset placement of an implant-supported prosthesis on bone stress distribution

✍ Scribed by E. Anitua; G. Orive


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
936 KB
Volume
89B
Category
Article
ISSN
1552-4973

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The aim of this study was to evaluate the influence of the straight alignment versus distal offset placement of an implant‐supported prosthesis (using implants with different diameters: 4 mm, 4.5 mm, and 5 mm) on bone stress distribution. 3D finite element models of a straight configuration and different offset configurations of the implant‐supported prosthesis (until 2.4 mm distal offset) were evaluated for the three implant diameters. A mesial load of 200 N and a distal load of 230 N were applied to the prosthesis. Results showed that implant offset provokes an opposite effect in bone stress depending on the exposed mesial or distal force. The former increases stress whereas the latter induces a dissipation of bone stress proportional to the offset. From these two forces, an optimal offset is created in which maximum bone stress is reduced in the range of 7–8% compared with the straight configuration. Increasing implant diameter from 4 to 5 mm decreased bone stress in 30% for all configurations. These data suggests that offset implant placement apart from enabling an optimal aesthetic restoration, reduces bone stress compared with the straight configuration. The use of wider implants permitted the reduction of the maximum bone stress in all the simulated configurations © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009


📜 SIMILAR VOLUMES


The influence of various occlusal materi
✍ Mujde Sevimay; Aslihan Usumez; Gurcan Eskitascıoglu 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 399 KB

## Abstract The aim of this numerical analysis was to evaluate the amount and localization of stress that occurs with various materials used in implant‐crown design under functional forces. Computer‐aided design techniques and a finite‐element stress analysis method were used for evaluation. A 4.1

The effects of impingement and dysplasia
✍ Salman Chegini; Martin Beck; Stephen J. Ferguson 📂 Article 📅 2009 🏛 Elsevier Science 🌐 English ⚖ 439 KB 👁 1 views

## Abstract Soft tissue damage has been observed in hip joints with pathological geometries. Our primary goal was to study the relationship between morphological variations of the bony components of the hip and resultant stresses within the soft tissues of the joint during routine daily activities.

Influence of crack closure on the stress
✍ R.S. Alwar; K.N.Ramachandran Nambissan 📂 Article 📅 1983 🏛 Elsevier Science 🌐 English ⚖ 790 KB

Plates with centraI through cracks subjected to bending is analysed taking into account the closure of ihe crack faces on the compression side. A r~ee-dimension finite element method emplo~g t~ee~~ensjon~ degenerate SOB element is used for the amdysis. The crack faces have been mode&d such that they

On using different finite elements with
✍ C. K. Lee; R. E. Hobbs 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 439 KB 👁 2 views

A series of numerical tests is carried out employing some commonly used finite elements for the solution of 2-D elastostatic stress analysis problems with an automatic adaptive refinement procedure. Different kinds of elements including Lagrangian quadrilateral and triangular elements, serendipity q