Femorodistal graft stenoses
โ Scribed by M. D. McShane; A. D. B. Chant; J. H. N. Wolfe
- Publisher
- John Wiley and Sons
- Year
- 1989
- Tongue
- English
- Weight
- 266 KB
- Volume
- 76
- Category
- Article
- ISSN
- 0007-1323
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
Abstract Detection and early correction of stenoses following femorodistal bypass grafting may prevent graft occlusion. We studied 43 grafts (36 saphenous vein and 7 human umbilical vein) prospectively by peroperative angiography and then by clinical assessment, post-exercise Doppler ankle pressures
The results of femorotibial bypass for limb salvage vary a great deal. One of the reasons for this might be the discrepancy between potential inflow and run-of into the foot. An arteriovenous fistula at the distal graft anastomosis may improve results but the best anatomical arrangement for the fist