## Abstract The myocardial oxygen extraction fraction (OEF) reflects the balance between myocardial oxygen supply and demand. The feasibility of quantifying myocardial OEF was demonstrated with MRI during pharmacologic vasodilation in dogs. Dipyridamole was infused intravenously to increase blood f
Feasibility study of myocardial perfusion and oxygenation by noncontrast MRI: comparison with PET study in a canine model
β Scribed by Kyle S. McCommis; Haosen Zhang; Pilar Herrero; Robert J. Gropler; Jie Zheng
- Publisher
- Elsevier Science
- Year
- 2008
- Tongue
- English
- Weight
- 1001 KB
- Volume
- 26
- Category
- Article
- ISSN
- 0730-725X
No coin nor oath required. For personal study only.
β¦ Synopsis
The purpose of this study was to examine the feasibility of quantifying myocardial blood flow (MBF) and rate of myocardial oxygen consumption (MVO(2)) during pharmacologically induced stress without using a contrast agent. The former was measured by the arterial spin labeling (ASL) method and the latter was obtained by measuring the oxygen extraction fraction (OEF) with the magnetic resonance imaging (MRI) blood oxygenation level-dependent effect and Fick's law. The MRI results were compared with the established positron emission tomography (PET) methods. Six mongrel dogs with induced acute moderate left coronary artery stenosis were scanned using a clinical PET and a 1.5-T MRI system, in the same day. Regional MBF, myocardial OEF and MVO(2) were measured with both imaging modalities. Correlation coefficients (R(2)) of the three myocardial indexes (MBF, OEF and MVO(2)) between MRI and PET methods ranged from 0.70 to 0.93. Bland-Altman statistics demonstrated that the estimated precision of the limits of agreement between MRI and PET measurements varied from 18% (OEF) to 37% (MBF) and 45% (MVO(2)). The detected changes in these indexes, at rest and during dobutamine stress, were similar between two image modalities. The proposed noncontrast MRI technique is a promising method to quantitatively assess myocardial perfusion and oxygenation.
π SIMILAR VOLUMES
## Abstract ## Purpose To determine the feasibility of T~2~βweighted BOLD imaging for estimating regional myocardial oxygen extraction fraction (OEF) and approximating perfusion reserve (MPR) simultaneously in a canine model with moderate coronary artery stenosis. ## Materials and Methods Eight
In dynamic contrast-enhanced MR imaging (DCE-MRI), sampling of the arterial input function (AIF) is required for analysis using the general kinetic model (GKM). Alternatively, the recently proposed reference region model (RRM) may be employed to avoid the need of acquiring the AIF. This study aimed
## Background: Myocardial perfusion single photon emission computed tomography (spect) occasionally fails to detect coronary stenosis in patients with coronary artery disease (cad). we evaluated coronary flow reserve (cfr) using oxygen 15-labeled water in areas with and without ischemia on techneti
Twenty-four patients were studied with both 201Tl-thallous chloride and 99mTc-TBI scintigraphy following exercise. Comparison of the two agents in detecting segmental myocardial ischemia and scar was made in 18 patients with evidence of coronary artery disease on 201Tl-thallous chloride scintigraphy
## Abstract ## Purpose: To validate noninvasive cardiac output measurements of phaseβcontrast magnetic resonance imaging (PCβMRI) and cine MRI using an invasive pressureβvolume (PV) loop technique on a swine model. ## Materials and Methods: We compared three methods for evaluating cardiac functi