𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Feasibility of FAIR imaging for evaluating tumor perfusion

✍ Scribed by Jee-Hyun Cho; Gyunggoo Cho; Youngkyu Song; Chulhyun Lee; Bum-Woo Park; Chang Kyung Lee; Namkug Kim; Sung Bin Park; Jong Soon Kang; Moo Rim Kang; Hwan Mook Kim; Young Ro Kim; Kyoung-Sik Cho; Jeong Kon Kim


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
346 KB
Volume
32
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose:

To evaluate the feasibility of flow‐sensitive alternating inversion recovery (FAIR) for measuring blood flow in tumor models.

Materials and Methods:

In eight mice tumor models, FAIR and dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) was performed. The reliability for measuring blood flow on FAIR was evaluated using the coefficient of variation of blood flow on psoas muscle. Three regions of interest (ROIs) were drawn in the peripheral, intermediate, and central portions within each tumor. The location of ROI was the same on FAIR and DCE‐MR images. The correlation between the blood flow on FAIR and perfusion‐related parameters on DCE‐MRI was evaluated using the Pearson correlation coefficient.

Results:

The coefficient of variation for measuring blood flow was 9.8%. Blood flow on FAIR showed a strong correlation with Kep (r = 0.77), percent relative enhancement (r = 0.73), and percent enhancement ratio (r = 0.81). The mean values of blood flow (mL/100 g/min) (358 vs. 207), Kep (sec^−^^1^) (7.46 vs. 1.31), percent relative enhancement (179% vs. 134%), and percent enhancement ratio (42% vs. 26%) were greater in the peripheral portion than in the central portion (P < 0.01).

Conclusion:

As blood flow measurement on FAIR is reliable and closely related with that on DCE‐MR, FAIR is feasible for measuring tumor blood flow. J. Magn. Reson. Imaging 2010;32:738–744. © 2010 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


FAIR true-FISP perfusion imaging of the
✍ Petros Martirosian; Uwe Klose; Irina Mader; Fritz Schick 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 313 KB

## Abstract Most arterial spin labeling (ASL) techniques apply echoplanar imaging (EPI) because this strategy provides relatively high SNR in short measuring times. Unfortunately, those techniques are very susceptible to static magnetic field inhomogeneities and perfusion signals from organs with f

FAIR true-FISP perfusion imaging of the
✍ Christina Schraml; Andreas Boss; Petros Martirosian; Nina F. Schwenzer; Claus D. 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 380 KB

## Abstract ## Purpose To evaluate the feasibility of quantitative perfusion MRI of the thyroid gland using an arterial spin labeling (ASL) method. ## Materials and Methods An ASL technique with flow‐sensitive alternating inversion‐recovery (FAIR) spin preparation and a true fast imaging in the

Feasibility and safety of high-dose aden
✍ Theodoros D Karamitsos; Ntobeko BA Ntusi; Jane M Francis; Cameron J Holloway; Sa 📂 Article 📅 2011 🏛 BioMed Central 🌐 English ⚖ 186 KB

The aim of the present study was to assess the tolerance and safety of a high-dose adenosine protocol (210mcg/ kg/min) in patients with inadequate hemodynamic response to the standard adenosine dose (140mcg/kg/ min) when undergoing CMR perfusion imaging. \* p<0.05 vs. rest. DBP, diastolic blood pres

Laser Doppler perfusion imaging: New tec
✍ Liu, David L.; Svanberg, Katarina; Wang, Ingrid; Andersson-Engels, Stefan; Svanb 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 335 KB 👁 2 views

## Background and objective: Several investigations indicated that laser doppler flowmetry on the liver surface reflects relative changes of the total liver blood flow. in this study, laser doppler perfusion imaging (ldi), monitoring the surface only, was used for measurements of tissue perfusion o