𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Feasibility and reproducibility of relaxometry, morphometric, and geometrical measurements of the hip joint with magnetic resonance imaging at 3T

✍ Scribed by Julio Carballido-Gamio; Thomas M. Link; Xiaojuan Li; Eric T. Han; Roland Krug; Michael D. Ries; Sharmila Majumdar


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
599 KB
Volume
28
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To test the feasibility of in vivo magnetic resonance T~1ρ~ relaxation time measurements of hip cartilage, and quantify the reproducibility of hip cartilage thickness, volume, T~2~, T~1ρ~, and size of femoral head measurements.

Materials and Methods

The hip joint of five human healthy volunteers, one subject with mild hip osteoarthritis (OA) and one subject with advanced hip OA, was imaged with magnetic resonance imaging (MRI) at 3T. Hip cartilage thickness, volume, T~1ρ~, and T~2~ were quantified, as well as the size of the femoral head. All imaging and analysis procedures were performed twice for the healthy volunteers to assess reproducibility.

Results

In vivo MR T~1ρ~ measurements of hip cartilage at 3T were feasible as demonstrated by high quality images and relaxation time maps. High levels of reproducibility were obtained for measurements of hip cartilage thickness (CV~SD~ = 2.19%), volume (CV~SD~ = 3.5%), T~2~ (CV~SD~ = 5.89%), T~1ρ~ (CV~SD~ = 2.03%), and size of femoral head (CV~SD~ = 0.49%). Mean T~2~ and T~1ρ~ relaxation time values for human healthy subjects were 28.38 (±2.66) msec and 38.72 (±3.84) msec, respectively. Mean T~2~ and T~1ρ~ relaxation time values for subjects with OA were 34.78 (±8.36) msec and 44.07 (±0.99) msec, respectively. T~2~ and T~1ρ~ values increased from the deep to the superficial layers.

Conclusion

Qualitative and quantitative results indicate that the MRI techniques presented in this study may be applied clinically to patients with OA of the hip to investigate these parameters at different stages of disease. J. Magn. Reson. Imaging 2008;28:227–235. © 2008 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Morphological features and clinical feas
✍ Yu De-xin; Ma Xiang-xing; Zhang Xiao-ming; Wang Qing; Li Chuan-fu 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 364 KB

## Abstract ## Purpose: To evaluate the detection of the thoracic duct using nonenhanced magnetic resonance imaging (MRI) and to determine the influence of some related disorders on the lymphatic duct. ## Materials and Methods: Highly fluid‐sensitive sequence and fat‐suppressed T2‐weighted imagi