𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Fatigue failure of helical compression spring in coke oven batteries

✍ Scribed by B.Ravi Kumar; Swapan K Das; D.K Bhattacharya


Publisher
Elsevier Science
Year
2003
Tongue
English
Weight
347 KB
Volume
10
Category
Article
ISSN
1350-6307

No coin nor oath required. For personal study only.

✦ Synopsis


The failure of a helical compression spring employed in coke oven batteries was analysed. Microstructural analysis and hardness measurements did not show any degradation of the spring material. Surface corrosion product was analysed by XRD and SEM-EDS. Sulphur and chlorine bearing compounds were detected. Macrofractography of the fracture surface revealed beach marks, indicating fatigue as the mode of fracture and surface pits. It was established that the spring failed due to corrosion fatigue.