𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Fatigue debonding of the roughened stem–cement interface: Effects of surface roughness and stem heating conditions

✍ Scribed by Leatha A. Damron; Do-Gyoon Kim; Kenneth A. Mann


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
393 KB
Volume
78B
Category
Article
ISSN
1552-4973

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The aim of this study was to determine the effects of cyclic loading on the debond process of a roughened stem–cement interface used in total hip arthroplasty. The specific goals were to assess the effects of two surgeon‐controlled variables (stem heating and degree of stem surface roughness) and to determine if an independent finite element‐based fracture mechanics model could be used to predict the debond response. A clamped cantilever beam geometry was used to determine the fatigue debond response of the stem–cement interface and was created using an experimental mold that simulated in vivo cementing conditions. A second experiment was performed using a torsion‐loading model representative of the stem–cement–bone composite. For both experiments, two stem heating (room temperature and 50°C) and surface roughness conditions (grit blasted: Ra = 2.3 and 5.1 μm) were used. Finally, a finite element model of the torsion experiment with provision for crack growth was developed and compared with the experimental results. Results from both experiments revealed that neither stem preheating nor use of a stem with a greater surface roughness had a marked effect on the fatigue debond response. There was substantial variability in the debond response for all cases; this may be due to microscopic gaps at the interface for all interface conditions. The debond rate from the finite element simulation (10^−7.31^ m/cycle) had a magnitude similar to the experimental torsion model (10^−(6.77 ± 1.25)^ m/cycle). This suggests that within the context of the experimental conditions studied here that the debond response could be assessed using a linear elastic fracture mechanics‐type approach. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006


📜 SIMILAR VOLUMES


Effects of prosthesis surface roughness
✍ Verdonschot, N. ;Tanck, E. ;Huiskes, R. 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 261 KB 👁 1 views

Retrieval studies suggest that the loosening process of the cemented femoral components of total hip arthroplasties is initiated by failure of the bond between the prosthesis and the cement mantle. Finite element (FE) analyses have demonstrated that stem-cement debonding has stressproducing effects

Integrity of the stem-cement interface i
✍ Kazuho Iesaka; William L. Jaffe; Frederick J. Kummer 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 151 KB 👁 1 views

## Abstract No consensus exists for the optimal surface finish on cemented total hip prosthesis stems. The purpose of this study was to determine the effects of stem finish and interfacial cement porosity on the integrity of the stem–cement interface. Simulated stems made of Co‐Cr, having polished

Effects of the initial temperature of ac
✍ Iesaka, K. ;Jaffe, W. L. ;Kummer, F. J. 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 123 KB 👁 1 views

It has been shown that preheating the femoral stem prior to insertion minimizes interfacial porosity at the stem-cement interface. In this study, the effects of methylmethacrylate monomer temperature prior to mixing on the properties of stem-cement interface and cement polymerization were evaluated