𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Fatigue behaviour of a commercial zinc-aluminium eutectoid alloy

✍ Scribed by J. Woodthorpe; Roger Pearce


Publisher
Elsevier Science
Year
1974
Tongue
English
Weight
355 KB
Volume
16
Category
Article
ISSN
0020-7403

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


Enthalpy of transformation and interfaci
✍ D Cheetham; F.R Sale πŸ“‚ Article πŸ“… 1974 πŸ› Elsevier Science βš– 706 KB

## Aus der Abhangigkeit der Umwandlungsenthalpie von der Gr6De der Grenzfliichenbereiche wurde die Grenzflachenenthalpie der Lamellen zu 0,72 & 0,ll J/m' gewonnen. Die Umwandlungsenthalpie massiver Eutektoide dieses Systems ist 46.0 & 1.0 kJ/kg bei 548 K. Die freie Energie der Lamellengrenzflilche

A comparative electrochemical study of c
✍ P. Premendra; H. Terryn; J. M. C. Mol; J. H. W. de Wit; L. Katgerman πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 German βš– 800 KB

## Abstract A comparative electrochemical study of commercially recycled AA5050 and model AA5050, in their as‐cast state, is carried out to investigate the effect of recycling and furthermore the effect of trace elements like Pb, Cu, etc on electrochemical activation and filiform corrosion (FFC) su

Electrochemical behaviour of a copper-al
✍ Elsayed A. Ashour; Badr G. Ateya πŸ“‚ Article πŸ“… 1997 πŸ› Elsevier Science 🌐 English βš– 841 KB

The electrochemical behaviour of a low-aluminium copper alloy (Alfa aluminium-bronze) in concentrated (1-8 N) NaOH is characteristically passive over broad potential regions, exhibiting passive currents that increase with alkali concentration. This passive behaviour is attributed to a duplex film, w

Influence of specimen configuration and
✍ Vikas Kumar Saxena; G. Malakondaiah; V.M. Radhakrishnan πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 425 KB

## Experimental investigations have been carried out to study the effect of specimen configuration and loading history on the crack growth behaviour of 2024-T3 aluminium alloy at room temperature. It has been observed that fatigue crack growth rate in specimens loaded symmetrically is higher than

Fatigue behaviour of 8090-Al-Li alloy in
✍ L. Bertolini; A. Cigada; G. Donzelli; T. Pastore; T. Ranucci πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 German βš– 473 KB

## Abstract The effect of an environment containing chloride on the fatigue behaviour of a 8090 Alο£ΏLiο£ΏMgο£ΏCu alloy was studied. Results were compared with those obtained on a traditional 2024 Alο£ΏCuο£ΏMg alloy. Fatigue and corrosion‐fatigue tests were carried out both on smooth specimens and riveted sa