## Abstract Balanced steady‐state free precession (SSFP) imaging is limited by off‐resonance banding artifacts, which occur with periodicity 1/TR in the frequency spectrum. A novel balanced SSFP technique for widening the band spacing in the frequency response is described. This method, called wide
Fat-water separation with alternating repetition time balanced SSFP
✍ Scribed by Tolga Çukur; Dwight G. Nishimura
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 615 KB
- Volume
- 60
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Balanced SSFP achieves high SNR efficiency, but suffers from bright fat signal. In this work, a multiple‐acquisition fat‐water separation technique using alternating repetition time (ATR) balanced SSFP is proposed. The SSFP profile can be modified using alternating repetition times and appropriate phase cycling to yield two spectra where fat and water are in‐phase and out‐of‐phase, respectively. The signal homogeneity and the broad width of the created in‐phase and out‐of‐phase profiles lead to signal cancellation over a broad stop‐band. The stop‐band suppression is achieved for a wide range of flip angles and tissue parameters. This property, coupled with the inherent flexibility of ATR SSFP in repetition time selection, makes the method a good candidate for fat‐suppressed SSFP imaging. The proposed method can be tailored to achieve a smaller residual stop‐band signal or a decreased sensitivity to field inhomogeneity depending on application‐specific needs. Magn Reson Med 60:479–484, 2008. © 2008 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Chemical shift‐based multipoint water‐fat separation methods have been applied in balanced steady‐state free precession (bSSFP) sequences because of the high signal‐to‐noise‐ratio (SNR) attainable. In this approach the echo formation is approximated to occur concurrently for both water
## Abstract There has been recent interest in positive‐contrast MRI methods for noninvasive tracking of cells labeled with superparamagnetic iron‐oxide nanoparticles. Low‐tip‐angle balanced steady‐state free precession sequences have been used for fast, high‐resolution, and flow‐insensitive positiv
## Abstract ## Purpose To assess a 3D radial balanced steady‐state free precession (SSFP) technique that provides submillimeter isotropic resolution and inherently registered fat and water image volumes in comparison to conventional T2‐weighted RARE imaging for lesion characterization in breast ma
## Abstract ## Purpose To implement IDEAL (iterative decomposition of water and fat using echo asymmetry and least squares estimation) water‐fat separation with 3D time‐of‐flight (TOF) magnetic resonance angiography (MRA) of intracranial vessels for improved background suppression by providing uni