𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Fat-suppressed three-dimensional dual echo dixon technique for contrast agent enhanced MRI

✍ Scribed by Jingfei Ma; Anthony T. Vu; Jong Bum Son; Haesun Choi; John D. Hazle


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
204 KB
Volume
23
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To develop a fast T1‐weighted, fat‐suppressed three‐dimensional dual echo Dixon technique and to demonstrate its use in contrast agent enhanced MRI.

Materials and Methods

A product fast three‐dimensional gradient echo pulse sequence was modified to acquire dual echoes after each RF excitation with water and fat signals in‐phase (IP) and opposed‐phase (OP), respectively. An on‐line reconstruction algorithm was implemented to automatically generate separate water and fat images. The signal to noise ratio (SNR) of the new technique was compared to that of the product technique in phantom. In vivo abdomen and breast images of cancer patients were acquired at 1.5 Tesla using both techniques before and after intravenous administration of gadolinium contrast agent.

Results

In phantom, the new technique yields a close to the theoretically predicted 41% increase in SNR in comparison to the product technique without fat suppression (FS). In vivo images of the new technique show noticeably improved FS and image quality in comparison to the images acquired of the same patients using the product technique with FS.

Conclusion

The three‐dimensional dual echo Dixon technique provides excellent image quality and can be used for T1‐weighted, fat‐suppressed imaging with contrast agent injection. J. Magn. Reson. Imaging 2006. © 2005 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Fast three-dimensional dual echo dixon t
✍ Huong Le-Petross; Vikas Kundra; Janio Szklaruk; Wei Wei; Gabriel N. Hortobagyi; 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 314 KB

## Abstract ## Purpose: To compare qualitative and quantitative measures of the contrast‐enhanced dual‐echo Dixon technique with the commonly used standard three‐dimensional (3D) gradient echo (spectrally selective fat suppression) technique (SS‐FS) in breast MRI exams (bMRI). ## Materials and Me

Pelvic imaging using a t1w fat-suppresse
✍ Daniel M. Cornfeld; Gary Israel; Shirley M. McCarthy; Jeffery C. Weinreb 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 302 KB

## Abstract ## Purpose To compare two T1‐weighted (T1W) fat‐suppressed sequences for 3D breath‐hold pre‐ and postcontrast fat‐suppressed T1W imaging of the female pelvis at 3T. ## Materials and Methods Pelvic MRI scans of 16 female patients were retrospectively identified who were scanned with t

T1-weighted 3D dynamic contrast-enhanced
✍ Basak E. Dogan; Jingfei Ma; Ken Hwang; Ping Liu; Wei Tse Yang 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 570 KB

## Abstract ## Purpose: To evaluate a single‐pass fast spoiled gradient echo (FSPGR) two‐point Dixon sequence and a gradient echo sequence with spectral fat suppression in their performance at 3 T for fat suppressed contrast‐enhanced bilateral breast imaging. ## Materials and Methods: Twenty pat

MRI of bone tumors: Fast STIR imaging as
✍ Osamu Tokuda; Noriko Hayashi; Naofumi Matsunaga 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 329 KB

## Abstract ## Purpose To compare the usefulness of short inversion recovery (STIR) and T1‐weighted, contrast‐enhanced, fat‐suppressed (T1W‐CEFS) sequences for the evaluation of bone tumors. ## Materials and Methods Eighteen patients with 19 bone tumors who underwent both STIR and T1W‐CEFS imagi