Fast Transient Fluorescence Technique for Studying Homopolymer Mobility in a Swelling Gel
✍ Scribed by Matem Erdogan; Önder Pekcan; Yusuf Yagcι
- Book ID
- 102486619
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 190 KB
- Volume
- 205
- Category
- Article
- ISSN
- 1022-1352
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Summary: The mobility of pyrene end‐capped polystyrene (Py‐PSt) trapped in swollen polystyrene gels (PSt) was investigated. PSt gels were prepared by free radical crosslinking copolymerization (FCC) of styrene (St) and ethylene glycol dimethacrylate (EGDM). The pyrene end‐capped polystyrene was produced by atom transfer radical polymerization (ATRP). After drying, these disc‐shaped PSt gels were left in a toluene solution of Py‐PSt of various molecular weights. During this process, Py‐PSt chains were trapped in the gel. These swollen gels were re‐dried in air and then immersed in pure toluene solution for monitoring the mobility of Py‐PSt chains in and out of the gel. These reswelling experiments were performed at room temperature in real time by monitoring pyrene lifetimes outside (τ~1~) and inside (τ~2~) of the PSt gel by using in‐situ fast transient fluorescence (FTRF) measurements. It was observed that τ~2~ values decrease as swelling proceeds; however, τ~1~ values stay constant during swelling. The Li‐Tanaka equation was employed to produce the swelling parameters. The swelling time constant, τ~c~ was found to increase as the crosslinker density of the gels and the molecular weight, $\overline M _{\rm n}$ of Py‐PSt chains were increased. It was observed that the collective diffusion coefficient, D~c~ decreased by increasing the molecular weight $\overline M _{\rm n}$ by obeying D~c~ ≈ M^−1^ law.
Position of the PSt gel in the fluorescence quartz cell before (a) and after (b) swelling. I~0~ and I~p~ are the excitation and the emission intensities.
magnified imagePosition of the PSt gel in the fluorescence quartz cell before (a) and after (b) swelling. I~0~ and I~p~ are the excitation and the emission intensities.
📜 SIMILAR VOLUMES
The time-resolved, fast transient fluorescence technique, which uses a strobe master system, was employed for studying the swelling of a disc-shaped poly-(methyl methacrylate) gel. The disc-shaped gel was prepared by free-radical copolymerization of methyl methacrylate and ethylene glycol dimethacry
A Strobe Master System (SMS) is introduced for studying the swelling of cylindrical densely (DG) and loosely (LG) formed gels. Gels were prepared by free radical copolymerization of methyl (methacrylate) (MMA) and ethylene glycol dimethacrylate (EGDM). Pyrene (P) was introduced as a fluorescence pro
## Abstract Fast transient fluorescence technique (FTRF) was employed for studying swelling of disc‐shaped poly(methyl methacrylate) (PMMA) gels, which were prepared by free radical copolymerization of methyl methacrylate (MMA) using various ethylene glycol dimethacrylate (EGDM) contents at 60 °C.