In this article, the authors illustrate the contributions of incidental magnetization transfer contrast (MTC) to the signal characteristics of patellar cartilage on routine, multiplanar fast spin-echo (FSE) images. Incidental MTC diminishes the signal of patellar cartilage by 30% on routine FSE scan
Fast spin-echo imaging of the knee: Factors influencing contrast
✍ Scribed by David W. Piraino; Peter A. Hardy; Jean P. Schils; Bradford J. Richmond; Jean A. Tkach; George H. Belhobek
- Publisher
- John Wiley and Sons
- Year
- 1993
- Tongue
- English
- Weight
- 955 KB
- Volume
- 3
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Conventional T2‐weighted spin‐echo magnetic resonance imaging of the knee requires a long TR. Fast spin‐echo (FSE) imaging can improve acquisition efficiency severalfold by collecting multiple lines of k space for each TR. Compromises in resolution, section coverage, and contrast inevitably result. The authors examined the compromises encountered in FSE imaging of the knee and discuss the variations in image contrast and resolution due to choices of sequence parameters. For short TR/TE knee imaging, FSE does not appear to offer any advantages, since the increased collection efficiency for one section reduces the available number of sections, so that the total imaging time for a given number of sections remains constant relative to conventional spin‐echo imaging. For T2‐weighted images, considerable time can be saved and comparable quality images can be obtained. This saved time can be usefully spent on increasing both the resolution of the image and its signal‐to‐noise ratio, while still reducing total acquisition time by a factor of two. The preferred FSE T2‐weighted images were acquired with a TR of 4,500 msec, TE of 120 msec, and eight echoes. The available number of sections is compromised, and the sequence remains sensitive to flow artifacts; however, the FSE sequence appears to be promising for knee imaging.
📜 SIMILAR VOLUMES
## Abstract Preliminary work has demonstrated that dynamic contrast material—enhanced magnetic resonance imaging improves the detection sensitivity for pituitary microadenomas. The authors present a new method of obtaining dynamic contrastenhanced pituitary images with a short TR/TE fast spin‐echo
A computer simulation has been used to calculate the effects of J coupling on the amplitudes of echoes produced by CPMG sequences. The program computes the evolution of the density matrix for different pulse intervals and can predict the signals obtainable from spin systems of any size and complexit
## Abstract ## Purpose To compare the usefulness of short inversion recovery (STIR) and T1‐weighted, contrast‐enhanced, fat‐suppressed (T1W‐CEFS) sequences for the evaluation of bone tumors. ## Materials and Methods Eighteen patients with 19 bone tumors who underwent both STIR and T1W‐CEFS imagi
## Abstract The purpose of our study was to assess the accuracy of inversion recovery–fast spin‐echo (IR‐FSE) imaging for the evaluation of chondromalacia of the patella. Eighty‐six patients were included, they underwent magnetic resonance (MR) examination and subsequent knee arthroscopy. Medial an
## Abstract The objective of this study was to compare the accuracy of T2‐weighted fast‐spin‐echo (FSE) and intermediate‐weighted spin‐echo (SE) MR imaging in the detection of meniscal tears. Seventy‐six patients (152 menisci) who had arthroscopic surgery after MR imaging of the knee were studied.