## Abstract Off‐resonance effects can cause image blurring in spiral scanning and various forms of image degradation in other MRI methods. Off‐resonance effects can be caused by both B0 inhomogeneity and concomitant gradient fields. Previously developed off‐resonance correction methods focus on the
Fast concomitant gradient field and field inhomogeneity correction for spiral cardiac imaging
✍ Scribed by Joseph Y. Cheng; Juan M. Santos; John M. Pauly
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 439 KB
- Volume
- 66
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Non‐Cartesian imaging provides many advantages in terms of flexibility, functionality, and speed. However, a major drawback to these imaging methods is off‐resonance distortion artifacts. These artifacts manifest as blurring in spiral imaging. Common techniques that remove the off‐resonance field inhomogeneity distortion effects are not sufficient, because the high order concomitant gradient fields are nontrivial for common imaging conditions, such as imaging 5 cm off isocenter in an 1.5 T scanner. Previous correction algorithms are either slow or do not take into account the known effects of concomitant gradient fields along with the field inhomogeneities. To ease the correction, the distortion effects are modeled as a non‐stationary convolution problem. In this work, two fast and accurate postgridding algorithms are presented and analyzed. These methods account for both the concomitant field effects and the field inhomogeneities. One algorithm operates in the frequency domain and the other in the spatial domain. To take advantage of their speed and accuracy, the algorithms are applied to a real‐time cardiac study and a high‐resolution cardiac study. Both of the presented algorithms provide for a practical solution to the off‐resonance problem in spiral imaging. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract As a consequence of the Maxwell equations, linear field gradients are accompanied by additional spatially dependent field components. A description of the Maxwell field terms is presented which explicitly takes into account the asymmetry of the gradient coil. It is shown both theoretica
## Abstract A balanced fast field echo (FFE) sequence (also referred to as true fast imaging with steady precession (true FISP)), based on projection reconstruction (PR) is evaluated in combination with real‐time reconstruction and interactive scanning capabilities for cardiac function studies. Car