Failure of transradial approach during coronary interventions: Anatomic considerations

✍ Scribed by Orazio Valsecchi; Angelina Vassileva; Giuseppe Musumeci; Roberta Rossini; Maurizio Tespili; Giulio Guagliumi; Laurian Mihalcsik; Antonello Gavazzi; Paolo Ferrazzi


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
317 KB
Volume
67
Category
Article
ISSN
1522-1946

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The anatomy of the radial artery has yet to be systematically studied from the perspective of using it as a route for catheter access. We prospectively performed angiography of the arteries of the upper limb to delineate the anatomic features of the radial artery as a way to determine the feasibility of using it as a route for coronary intervention. We studied 2,211 consecutive patients submitted to transradial cardiac catheterization. In all patients, an angiography of the upper limb arteries was performed before and after procedure. Radial puncture was successful in 98.9% of patients. At angiography, anatomic variations of upper limb arteries were noted in 505 patients (22.8%) and included tortuous configurations (3.8%), stenosis (1.7%), hypoplasias (7.7%), radioulnar loop (0.8%), abnormal origin of the radial artery (8.3%), and lusoria subclavian artery (0.45%). Overall procedural success by transradial approach was 97.5%. Patients with anatomic variations of radial artery had a significantly lower puncture (96.2% vs 99.7%, P < 0.0001) and procedural (93.1% vs 98.8%, P < 0.0001) success. The procedure was successfully performed by radial approach in 98.8% of patients with tortuous configurations, 91.9% of radial stenosis, 93.9% of hypoplastic radial artery, 83.3% of radioulnar loop, 96.7% of radial axillary origin, and 60% of lusoria subclavian artery setting. Anatomic variations of the radial artery are not rare. However, they do not represent an important limitation in transradial approach if they are well documented previously. Β© 2006 Wiley‐Liss., Inc.


πŸ“œ SIMILAR VOLUMES


Use of the sheathless guide catheter dur
✍ Mamas Mamas; Savio D'Souza; Cara Hendry; Razwan Ali; Heather Iles-Smith; Karen P πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 301 KB πŸ‘ 2 views

## Abstract Objective: The aim of this study is to investigate the feasibility of using a 6.5 Fr sheathless guide catheter as a default system in transradial (TRA) percutaneous coronary intervention (PCI). Background: TRA PCI has been shown to reduce mortality rates through a reduction in access si

Perforation of the sinus of Valsalva by
✍ Francesco Tomassini; Andrea Gagnor; Ferdinando Varbella πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 953 KB

## Abstract Iatrogenic dissection of the sinus of Valsalva or of the ascending aorta is a rare but potentially fatal event, during the percuteneous coronary intervention (PCI). We reported a case of perforation of the sinus of Valsalva by guiding catheter during PCI via the right transradial approa