✦ Synopsis


Thirteen failed stem of Total Hip Replacement were studied: 9 were Charnley THR from an homogeneous series, which gives an incidence of 2.4% of stem fractures with a follow-up of 9-16 years; 4 were Mueller THR. Fatigue fracture of the stem occurred by defective support of the proximal part of the femur, following resorption of the calcar. In all cases reactive tissue to foreign body particles, metal and polyethylene, was found where bone resorption occurred. In Mueller THR wear of the cup produced the large amount of polyethylene particles; in Charnley THR metal particles prevailed and corrosion of the stem is suggested to be the initiating factor.


πŸ“œ SIMILAR VOLUMES


Total hip replacement after nailing fail
✍ G. HΓ€gglund; B. NordstrΓΆm; L. Lidgren πŸ“‚ Article πŸ“… 1984 πŸ› Springer 🌐 English βš– 190 KB

Forty patients were treated by means of total hip arthroplasty after nailing of femoral neck fractures had failed Their average age was 73 years. Thirty-eight patients were still alive after 2 years and were reviewed Two hips dislocated, but there was no early mortality The results regarding pain, w

Early failures of total hip replacement:
✍ Elena Losina; Jane Barrett; Nizar N. Mahomed; John A. Baron; Jeffrey N. Katz πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 96 KB

## Objective: To determine whether provider volume is associated with early failures following total hip replacement (thr) requiring revision. ## Methods: Claims data were analyzed to follow a cohort of 57,488 medicare beneficiaries who underwent elective primary thr in 1995-1996 in 3,044 hospita

Clinical reviews: Particulate debris and
✍ Dr. Murali Jasty πŸ“‚ Article πŸ“… 1993 πŸ› Wiley (John Wiley & Sons) 🌐 English βš– 419 KB

Largely through the pioneering advances made by John Charnley,' total joint replacements with man-made metal and plastic materials have revolutionized the surgical treatment of millions of patients with end-stage hip and knee arthritis for the past 30 years. Approximately 500,000 total hip and knee

Friction and stem stiffness affect dynam
✍ Jan Herman Kuiper; Rik Huiskes πŸ“‚ Article πŸ“… 1996 πŸ› Elsevier Science 🌐 English βš– 825 KB

## Abstract Large cyclic movements between the femoral stem and bone during the first weeks after total hip arthroplasty may hamper bone ingrowth and adversely affect the eventual success of the arthroplasty. Little is known, however, about the magnitude of the motions and its relationship to desig

Blood loss in total hip replacement
✍ P. A. Flordal; G. Neander πŸ“‚ Article πŸ“… 1991 πŸ› Springer 🌐 English βš– 602 KB

Two hundred and twelve total hip replacements performed in one clinic over 1 year were reviewed. The mean operative time was 89 min and mean total blood loss 1090 ml. Homologous blood was administered to 74% of the patients. Blood loss was dependent on sex, body weight and height, but these correlat