Combined cycle power plants (CCPPs) have an important role in power generation. The objective of this paper is to evaluate irreversibility of each part of Neka CCPP using the exergy analysis. The results show that the combustion chamber, gas turbine, duct burner and heat recovery steam generator (HR
Failure analysis of turbo-generator of a 10 MW captive power plant
β Scribed by N. Parida; S. Tarafder
- Publisher
- Elsevier Science
- Year
- 2001
- Tongue
- English
- Weight
- 1008 KB
- Volume
- 8
- Category
- Article
- ISSN
- 1350-6307
No coin nor oath required. For personal study only.
β¦ Synopsis
The failure analysis of a disc and a few of the rotor parts of a turbo-generator of a 10 MW captive power plant has been made. It was found that a part of the rim of the 23rd disc, which had cracked by fatigue, became unstable and was Β―ung o. This hit the diaphragm and the diaphragm carrier in its vicinity and led to their catastrophic failure.