## Abstract This study was undertaken to determine how accurately total graft force and loadโsharing between graft segments could be set and maintained during augmented anterior cruciate ligament (ACL) reconstruction in the goat knee. Special procedures were developed to reduce the effect of tissue
Factors affecting graft force in surgical reconstruction of the anterior cruciate ligament
โ Scribed by Dr. Jack L. Lewis; William D. Lew; Lars Engebretsen; Robert E. Hunter; Curtis Kowalczyk
- Publisher
- Elsevier Science
- Year
- 1990
- Tongue
- English
- Weight
- 781 KB
- Volume
- 8
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
โฆ Synopsis
Abstract
The effect of the maximum unloaded graft length (L~o~) and femoral fixation hole location on graft force with the knee under anteriorly directed tibial loads was measured in five fresh cadaver knees with a reconstruction of the anterior cruciate ligament (ACL). The reconstruction was performed using a composite graft consisting of the semitendinosus and gracilis tendons augmented with the Kennedy ligament augmentation device (LAD). Buckle transducers were used to measure ligament and graft forces. The total graft force was adjusted to match the intact ACL at 30ยฐ flexion using a forceโsetting method so that a standardized reference configuration could be repeatedly obtained. The graft force was highly sensitive to L~0~, typically changing by 50% with a change in L~0~ of 3 mm. Variation in femoral hole location of 5 mm anterior, posterior, proximal, and distal to the anatomic position produced changes in graft force, particularly at 60ยฐ and 90ยฐ flexion; however, these changes were not statistically significant. The effect of femoral hole location varied considerably between knees. This variability makes predicting proper hole placement difficult, and suggests the need to adjust each knee at surgery to account for this variable femoral hole position sensitivity.
๐ SIMILAR VOLUMES
## Abstract We compared the mechanical behavior of two common hamstring graft constructs that are frequently used for reconstruction of the anterior cruciate ligamentโGraft A: quadrupled semitendinosus tendon fixed with titanium button/polyester tape and suture/screw post, and Graft B: a double sem
## Abstract The two functional bundles of the anterior cruciate ligament (ACL), namely, the anteromedial (AM) and posterolateral (PL) bundles, must work in concert to control displacement of the tibia relative to the femur for complex motions. Thus, the replacement graft(s) for a torn ACL should po
An existing goat model was used to measure in vivo graft forces during walking, to determine if the forces set at surgery change over time under the same external load and if the forces in the graft during in vivo function can be dictated by the forces set at surgery. The anterior cruciate ligament
## Abstract An isometer, a highly compliant springโscale device for measuring suture displacement, has been used intraoperatively by surgeons to select the optimal placement of the femoral tunnel for an anterior cruciate ligament graft. The isometer measures the displacement of a suture centered in