A Β―ow injection spectrophotometric method for the determination of carbofuran in commercial pesticide formulations was developed. The determination involves on-line hydrolysis of the extracted carbofuran at room temperature with sodium hydroxide. The resulting carbofuran-phenol is coupled with diazo
Facile and sensitive determination of selenium (IV) in pharmaceutical formulations by flow injection spectrophotometry
β Scribed by Kailasa Suresh Kumar; Kanchi Suvardhan; Seong Ho Kang
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 119 KB
- Volume
- 97
- Category
- Article
- ISSN
- 0022-3549
No coin nor oath required. For personal study only.
β¦ Synopsis
An automated flow injection spectrophotometric method has been developed for the rapid, simple, selective, and sensitive determination of selenium (IV) from various pharmaceutical multivitamin and mineral formulations. The method was based on the oxidation of 4-aminoantipyrine (4-amino-l,2-dihydro-1,5-dimethyl-2-phenyl-3H-pyrazole-3-one; 4-AAP) by selenium in presence of acidic medium and the coupling with N-(naphthalen-l-yl)ethane-1,2-diamine dihydrochloride (NEDA) to give a violet color derivative. Gilson P2 mini pulse peristaltic pump has been used for introducing the selenium (IV), dilute HCl, 4-AAP and NEDA solutions into reaction coil by an automatic system. The absorbance of the 4-AAP-NEDA color derivative was measured at 563 nm after a reaction time of 3 min in stop flow of 4-AAP-NEDA. Beer's law was obeyed for selenium in the concentration range 0.05-5.0 microg mL(-1) and Sandell's sensitivity was found to be 0.00286 microg cm2. The performance of the present method was compared with the official method in terms of Student's F- and t-tests, and no significant difference was observed. This method was found to be suitable for estimating the selenium (IV) concentration in various pharmaceutical multivitamin and mineral formulations such as tablets and capsules.
π SIMILAR VOLUMES
A simple design of a polarographic flow-through cell is proposed in which a conventional dropping mercury electrode (DME) is used as working electrode, and a mercury pool and a platinum wire are used as the reference and counter electrodes, respectively. The mercury droplets falling from the DME coa
## Abstract A flow injection method with chemiluminescence detection is reported for the determination of vitamin A. The method is based on the enhancement effect of vitamin A on chemiluminescence of tris(2,2β²βbipyridyl)Ru(II)βCe(IV) in acidic medium. The proposed procedure is used to quantitate vi
## Abstract This paper describes the determination of diclofenac (DCF) in pharmaceutical formulations using flow injection method with multiple pulse amperometric detection. Unmodified boronβdoped diamond (BDD) is used as working electrode and 0.10β mol L^β1^ sulfuric acid as supporting electrolyte.
## Abstract A chemiluminescent method using flow injection (FI) was investigated for rapid and sensitive determination of enalapril maleate and atenolol, which are used in the treatment of hypertension. The method is based on the sensitizing effect of these drugs on the Ce(IV)βsulfite reaction. The