Dedicated to Professor Dr. Wolf-Dieter Deckwer on the occasion of his 60th birthday Oxygen desorption from organic liquids (ethanol (96 %), 1-butanol, toluene) and water into nitrogen gas has been studied with an optical sensor. Gas hold-ups and volumetric mass transfer coefficients have been determ
Experimental Study of Oxygen Mass Transfer Coefficient in Bubble Column with High Temperature and High Pressure
✍ Scribed by H. Jin; D. Liu; S. Yang; G. He; Z. Guo; Z. Tong
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 648 KB
- Volume
- 27
- Category
- Article
- ISSN
- 0930-7516
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The volumetric gas‐liquid mass transfer coefficient, k__~L~α, for oxygen was studied by using the dynamic method in slurry bubble column reactors with high temperature and high pressure. The effects of temperature, pressure, superficial gas velocity and solids concentration on the mass transfer coefficient are systemically discussed. Experimental results show that the gas‐liquid mass transfer coefficient increases with the increase in pressure, temperature, and superficial gas velocity, and decreases with the increase in solids concentration. Moreover, k~L~__α values in a large bubble column are slightly higher than those in a small one at certain operating conditions. According to the analysis of experimental data, an empirical correlation is obtained to calculate the values of the oxygen volumetric mass transfer coefficient for a water‐quartz sand system in two bubble columns with different diameter at high temperature and high pressure.
📜 SIMILAR VOLUMES
## Abstract A semi‐theoretical approach for predicting __k__~L~__a__ values (referred to liquid volume) in 18 organic liquids [acetone, aniline, 1‐butanol, benzene, cyclohexane, decalin, 1,2‐dichloroethane, 1,4‐dioxane, ethanol (96%), ethylacetate, ethylbenzene, ligroin, methanol, nitrobenzene, 2‐p
## Abstract The present contribution is dedicated to experimental and theoretical assessment of microbiological process heterogeneities of the high‐pressure (HP) inactivation of __Lactococcus lactis__ ssp. __cremoris__ MG 1363. The inactivation kinetics are determined in dependence of pressure, pro
A new heat transfer enhanced tube\*the inside and outside spirally triangle "nned tube with small spiral angles (IOSTF tube)\*was developed and manufactured for improving the performance of high-pressure preheaters. The triangle #utes with small spiral angle on the outside surface of the IOSTF tube