𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Experimental study of fire-resistant steel H-columns at elevated temperature

✍ Scribed by Kuo-Chen Yang; Hung-Hsin Lee; Olen Chan


Publisher
Elsevier Science
Year
2006
Tongue
English
Weight
607 KB
Volume
62
Category
Article
ISSN
0143-974X

No coin nor oath required. For personal study only.

✦ Synopsis


This paper presents the experimental studies of axially loaded fire-resistant steel columns under elevated temperature. With the advancement of metal production, fire-resistant steel with enhanced mechanical properties at elevated temperatures has been developed recently. However, extensive research work is needed in order for the application of fire-resistant steel in building structures. In this study, a series of fire-resistant steel columns was loaded to their ultimate states at specified temperature. The effects of width-thickness ratios, slenderness ratios and residual stress on the performance of fire-resistant steel H-columns are examined. Based on this study, it is found that the section property of fire-resistant H-columns should be at least a non-compact section in order to prevent local buckling. Column strength is sensitive to slenderness ratio at elevated temperature. The strength of a slender column decreased sharply especially for temperatures above 600 β€’ C. It is also found that the failure mode of steel columns changed from inelastic global buckling at room temperature to local buckling at elevated temperature, due to the release of residual stress in fire. An analytical model is proposed which is able to predict the behavior of fire-resistant steel H-columns under elevated temperature. Design guidelines are also proposed for the design of fire-resistant steel columns in fire conditions.


πŸ“œ SIMILAR VOLUMES


Experimental study on local buckling of
✍ Kuo-Chen Yang; Sheng-Jin Chen; Cun-Ci Lin; Hung-Hsin Lee πŸ“‚ Article πŸ“… 2005 πŸ› Elsevier Science 🌐 English βš– 858 KB

The structural behavior of stub columns using fire-resistant steel has been investigated experimentally under uniform fire load. The newly-developed fire-resistant steel is proven to have higher strength at elevated temperature than that of conventional steel. Also, the requirement of fireprotection

Experimental and analytical investigatio
✍ S. Spyrou; J.B. Davison; I.W. Burgess; R.J. Plank πŸ“‚ Article πŸ“… 2004 πŸ› Elsevier Science 🌐 English βš– 803 KB

When steel-framed structures are subjected to fire, their ability to sustain loads is severely impaired and the action of the joints is of particular concern. To date, data on the response of steel joints at high temperatures has been gathered from full-scale furnace tests. In an attempt to establis

The erosion-corrosion resistance of unco
✍ E. Huttunen-Saarivirta; S. Kalidakis; F.H. Stott; V. Rohr; M. SchΓΌtze πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 German βš– 670 KB

In this paper, some results from a study of the erosion-corrosion resistance of uncoated and aluminized 12% chromium steel in a fluidized-bed rig are reported. The aims of the research are to establish and compare the erosion-corrosion resistance of these materials for possible applications as heat