In order to increase the temperature lift and efficiency of single-absorption heat transformers there are other possible arrangements. Double-absorption heat transformers have a relatively simple design and smaller size compared to two-stage heat transformers. In this work, the thermodynamic perform
EXPERIMENTAL PERFORMANCE OF THE SYSTEM WATER/MAGNESIUM CHLORIDE IN A HEAT TRANSFORMER
✍ Scribed by R. M. Barragán; V. M. Arellano; C. L. Heard; R. Best; F. A. Holland
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 208 KB
- Volume
- 21
- Category
- Article
- ISSN
- 0363-907X
No coin nor oath required. For personal study only.
✦ Synopsis
Absorption heat transformers are devices with the unique capability of raising the temperature of part of a low grade heat source whilst simultaneously rejecting the rest of the heat at a lower temperature. The gross temperature lift that could be attained in the process depends on the characteristics of the working pair. Many combinations of working fluid/absorbent have been proposed although until now the water/lithium bromide system is the most widely used. Experimental results for the water/magnesium chloride working pair in an absorption heat transformer are presented. Two different ranges for the absorber temperature were investigated. The absorber temperature varied from 81 to 89°C and from 91 to 101°C. For the first case, the gross temperature lift was calculated between 7•8 and 10•2°C whilst for the second case the gross temperature lift was found to be between 15 and 18•4°C. For both sets of experiments, the heat input was maintained constant and the calculated coefficient of performance was related to the absorber temperature, the flow ratio and the effectiveness of the economizer.
📜 SIMILAR VOLUMES
Hourly thermal performance (both in laboratory and field conditions) of three designs of built-in-storage solar water heating systems of 100 litres capacity each has been reported. A different storage tank design is used in each of the three cases. Design I consists of three tanks connected in serie
Hot water tanks with a built-in water-heating coil are commonly used in district heating house stations in Denmark for domestic hot water (DHW) production and storage. In this study, an evaluation of the dynamic performance of a hot water tank with built-in heating coil is carried out by applying a