Experimental analysis of the electric field distribution in GaAs radiation detectors
✍ Scribed by Andrea Perd’ochová-Šagátová; Vladimír Linhart; František Dubecký; Bohumír Zaťko; Vladimír Nečas; Stanislav Pospíšil
- Publisher
- Elsevier Science
- Year
- 2006
- Tongue
- English
- Weight
- 200 KB
- Volume
- 563
- Category
- Article
- ISSN
- 0168-9002
No coin nor oath required. For personal study only.
✦ Synopsis
We describe the results of experimental studies of Liquid Encapsulated Czochralski (LEC) semi-insulating GaAs detectors with different contact areas. The detector active area spreading at different applied bias is proven by three various experiments. In the first, the scan of the detector electrode and adjacent area was performed using the 660 nm pulsed laser beam, with a spot diameter of 50 mm. The other experiments use the spectra measured by tested detectors, when irradiated by 241 Am a source (5.48 MeV). The experiments show relation between bias voltage applied and the range of active detector area from the edge of the detector contact.