Uropathogenic adhesion was measured using a range of polymer materials with differing surface tension properties. Experiments were carried out in the presence of phosphate buffered saline (controls), Tamm Horsfall protein (THP), and human urine with quantitation by image analysis. The results showed
Exclusion of uropathogen adhesion to polymer surfaces byLactobacillus acidophilus
β Scribed by Hawthorn, Lesley Ann ;Reid, Gregor
- Publisher
- John Wiley and Sons
- Year
- 1990
- Tongue
- English
- Weight
- 471 KB
- Volume
- 24
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
The ability of bacteria to adhere to surfaces is a major cause of concern in the use of biomaterial substrates. The adhesion of Staphylococcus epidermidis strain 1938 was examined using image analysis and was found not to correlate with polymer surface tension, unlike that of Lactobacillus acidophilus, which adhered to more hydrophobic polymers. A fimbriated uropathogenic E. coli strain showed very low levels of adherence to the biomaterials. Precoating the polymers with lactobacilli significantly reduced the staphylococcal and E. coli adhesion, a result which could have clinical significance. An additional finding was that the interaction of staphylococci and E. coli with lactobacilli coated polymers altered the adhesion profile of the latter. Lactobacilli appeared to detach from polymers of low surface tension and reattach to polymers with high surface tensions. This resulted in the highest levels of exclusion of uropathogens being found for lactobacilli-coated glass and sulfonated polystyrene, both of which are hydrophilic (with high surface tensions). These results demonstrate that lactobacilli can be used to coat biomaterial surfaces leading to a reduced adhesion of uropathogens.
π SIMILAR VOLUMES
Results of the kinetics of adhesion of granulocytes as well as fresh and glutaraldehydefixed erythrocytes, suspended in Hanks Balanced Salt Solution (HBSS; pH 7.2, ionic strength of 0.15) to various polymeric substrates are presented. Cell adhesion increases rapidly initially and reaches a plateau v
An exact discrete numerical solution to the Grabowski model for predicting cell adhesion to polymer surfaces is discussed. The solution technique allows the possibility of taking into account cell-cell interactions within the flow situation and the multistep process involved in thrombus formation. T
## Abstract Fibrous membranes (nonwoven meshes) prepared via electrospinning technique have great potential in tissue engineering. This work is the first study on the behaviors of blood platelets at the nanostructured surface generated by electrospinning. Poly[acrylonitrileβ__co__β(__N__βvinylβ2βpy