A flow-mixing calorimeter has been used to measure the excess molar enthalpy H E m ( p o ) of (carbon dioxide + dioxane)(g) and (propane + dioxane)(g) at standard atmospheric pressure ( p o ) = 0.101325 MPa over the temperature range T = (373.2 to 433.2) K. The measurements on (propane + dioxane) we
Excess molar enthalpies of (carbon dioxide  +  ethene) in the liquid and near-critical regions
β Scribed by C.J. Wormald; J.M. Eyears
- Publisher
- Elsevier Science
- Year
- 2001
- Tongue
- English
- Weight
- 263 KB
- Volume
- 33
- Category
- Article
- ISSN
- 0021-9614
No coin nor oath required. For personal study only.
β¦ Synopsis
Flow calorimetric measurements of the excess molar enthalpy H E m for {xCO 2 + (1 -x) C 2 H 4 } are described. The measurements cover the range T = 260.95 K to T = 315.75 K at pressures from 3.5 MPa to 12.6 MPa. Liquid phase measurements were made at the pressure 11.0 MPa over the range T = 260.95 to T = 300.45 K, and at pressures slightly greater than the saturation pressure of ethene or the critical pressure locus for the mixture. At x = 0.5 and at the four temperatures (285.85, 300.45, 306.25, and 315.75) K, excess enthalpy measurements were made over a range of pressures from 3.0 MPa to 12.6 MPa. The measurements at (285.85 and 300.45) K traverse the critical locus for the mixture, and those at (306.25 and 315.75) K are in the supercritical region. The measurements are compared with curves generated from the Patel-Teja equation of state, which does not quite fit the measurements but reproduces the main features of the observed behaviour.
π SIMILAR VOLUMES
Measurements of the enthalpy of solution for carbon dioxide in (water + monoethanolamine, or diethanolamine, or N -methyldiethanolamine) and in (water + monoethanolamine + N -methyldiethanolamine) at T = 298.15 K have been made by isothermal displacement calorimetry. The estimated uncertainty is bet
TABLE 1. Densities Ο for the pure liquids at T = 298.15 K Ο/(gβ’cm -3 ) Liquid expt lit 1-Chlorobutane 0.88069 0.88079 (4) 1-Butanol 0.80575 0.80576 (5)
A flow mixing calorimeter followed by a vibrating-tube densimeter has been used to measure excess molar enthalpies H E m and excess molar volumes V E m of {xC 3 H 8 + (1 -x)SF 6 }. Measurements over a range of mole fractions x have been made at the pressure p = 4.30 MPa at eight temperatures in the
A high-pressure expansion apparatus, described previously, has been used to measure the densities of {xXe + (1 -x)C 2 H 4 } at x = (0.0278, 0.489, and 0.759). The results reported in this paper cover the homogeneous gas and the liquid regions in the temperature range from 273 K up to near the critic
Excess molar volumes V E m have been calculated from measured density values over the whole composition range at T = 298.15 K and atmospheric pressure for six {N -methyl-2-pyrrolidinone + 1,1-dimethylethyl methyl ether, or dipropyl ether, or 1,1-dimethylpropyl methyl ether, or diisopropyl ether, or