This investigation evaluates the effectiveness of the ultrasonic sensing of methanol concentration and establishes two regression models based on measurements of sound propagation speed against methanol concentration. Uncertainty analysis reveals that propagation distance and equipment sampling rate affect the accuracy of sound speed measurement. An ultrasonic blind region is present because sensitivity declines at a temperature of approximately 63 β€’ C. The accuracy of measurement of the speed of sound is increased by the calibration of transducer distance because of variations in temperature. Increasing the transducer distance to 20 mm reduces the error between the theoretical and experimental speed of sound to 0.59 m/s. If the transducer distance is well calibrated, then the range of temperatures associated with ultrasonic blindness is reduced to 2-6 β€’ C. Frequency shift and attenuation in the blind temperature range are also investigated, indicating that these two parameters are insensitive to methanol concentration.


πŸ“œ SIMILAR VOLUMES


Measurement of methanol crossover in dir
✍ Satoru Hikita; Kimitaka Yamane; Yasuo Nakajima πŸ“‚ Article πŸ“… 2001 πŸ› Elsevier Science 🌐 English βš– 333 KB

In a direct methanol fuel cell (DMFC) with a Na"on membrane, a methanol solution fed to the anode permeates to the cathode. This phenomenon causes the depolarization loss at the cathode and the DMFC performance grows worse. In this research, by continuously measuring the concentration of CH OH, CO a

Structural optimization of the direct me
✍ Xianglin Li; Amir Faghri; Chao Xu πŸ“‚ Article πŸ“… 2010 πŸ› Elsevier Science 🌐 English βš– 599 KB

In a high-concentration direct methanol fuel cell (HC-DMFC), the methanol crossover is typically decreased to an acceptable level by two main mechanisms: high methanol transport resistance between the anode reservoir and the membrane electrode assembly (MEA), and high water back flow from the cathod

Influence of Methanol Crossover on the F
✍ Q.-Z. Lai; G.-P. Yin; Z.-B. Wang; C.-Y. Du; P.-J. Zuo; X.-Q. Cheng πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 143 KB πŸ‘ 1 views

## Abstract The effect of methanol crossover on the fuel utilization of a passive direct methanol fuel cell (DMFC) was reported. The results revealed that the Faradaic efficiency decreased from 46.9 to 17.4% when methanol concentration increased from 1.0 to 8.0 mol L^–1^ at the lower current densit

Modeling of Liquid Direct Methanol Fuel
✍ Anette Siebke; Frank Meier; Gerhart Eigenberger; Manfred Fischer πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 German βš– 53 KB πŸ‘ 1 views