Evaluation of toxicity of medical devices using Spirotox and Microtox tests: I. Toxicity of selected toxicants in various diluents
✍ Scribed by Na?ecz-Jawecki, Grzegorz ;Rud?, Beata ;Sawicki, J�zef
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 65 KB
- Volume
- 35
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
✦ Synopsis
Significant effort has been directed toward developing in vitro alternatives, which can be the first step of toxicity analysis. Tissue culture assays are currently the most popular in vitro tests for evaluating acute toxicity. The possibility of applying two bioassays using microorganisms in assessing the toxicity of extracts of medical devices was investigated. The Microtox test system-a luminescent bacteria toxicity test-assesses changes in light output from a luminescent bacteria, Vibrio fischeri. Spirotox used a large ciliate protozoan: Spirostomum ambiguum. The most widely used extraction solvent, 0.9% NaCl, must be concentrated up to 2% for Microtox and diluted nine times for the Spirotox test.
The organic solvents ethanol, DMSO, and polyethylene glycol 400 were not toxic in either test in concentrations of 1-2%. The toxicity of reference compounds Hg, Cd, Zn, Pb, and SDS was examined in various diluents. The sequence of toxicity of the tested compounds in Spirotox and Microtox was: Hg > Cd > Zn > Pb > SDS, and Hg > Pb = Zn > SDS > Cd, respectively. Addition of organic solvents changed the toxicity of compounds tested in 60% of Spirotox tests and only in 25% of Microtox tests. Changes were low, not exceeding 100% in almost all cases. No correlation was observed between diluent and toxicant in either bioassay.
📜 SIMILAR VOLUMES
The toxicities of effluents from three Ontario, Canada, refineries were assessed with microbes, plants, invertebrates, and fish. Acute toxicity was assessed by the Microtox test, an assay based on electron transport activity in submitochondrial particles, and Daphnia magna (water flea) and Oncorhync
## Abstract The hemolytic potential of pure ethylene oxide in solution was evaluated as a function of initial ethylene oxide concentration in three test systems, diluted whole blood in isotonic saline, erythrocytes washed and resuspended in isotonic saline, and erythrocytes washed and resuspended i
The industrial and sanitary use of dithiocarbamates DTCs is on the rise, and the synthesis of new derivatives has increased the field of their application. Both positive and negative pharmacological and toxicological effects have been documented for DTCs. The development and application of new DTCs