𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Evaluation of the micromechanical elastic properties of potential bone-grafting materials

✍ Scribed by Tsutomu Nomura; J. Lawrence Katz; Michael P. Powers; Chikara Saito


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
423 KB
Volume
73B
Category
Article
ISSN
1552-4973

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The micromechanical elastic properties of potential bone‐graft materials were compared with that of the human mandible. Six different potential bone‐replacement materials were used: Bio‐Oss (Osteohealth), OsteoGraf/N‐700 (Ceramed), Pepgen P15 (Ceramed), Interpore200 (Interpore Cross International), Allogro (Ceramed), and Dynagraft (GenSci Dental). As a control, mandibular cortical bone was obtained from a 17‐year‐old woman. Micromechanical elastic property analysis was obtained with the use of a UH3 scanning acoustic microscope (Olympus Co., Tokyo, Japan) (SAM) at 400 MHz in the burst mode. Each sample was measured at three areas. The data were analyzed statistically by SPSS (SPSS, Inc.) with the use of the Student t test. In human bone, the reflection coefficients r of the x dimension (r = 0.75 ± 0.01) was statistically higher than those of the y (0.72 ± 0.05) and the z (0.72 ± 0.01) directions. The order of stiffness magnitude was found to be Pepgen (r = 0.73 ± 0.05) ≥ OsteoGraf (0.72 ± 0.03) > Bio‐Oss (0.71 ± 0.02) > Interpore (0.69 ± 0.10) > Dynagraft (0.43 ± 0.05) > Allogro (0.36 ± 0.04). For these samples, Interpore alone showed a large deviation in properties in the same specimen. With regard to the elastic properties solely, bone‐grafting materials made from bovine or processed marine coral appear to be reasonable choices as graft materials. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 73B: 29–34, 2005


📜 SIMILAR VOLUMES


Evaluation of bone-grafting materials in
✍ Dr. George F. Muschler; Bryan Huber; Thomas Ullman; Richard Barth; Kirk Easley; 📂 Article 📅 1993 🏛 Elsevier Science 🌐 English ⚖ 990 KB

## Abstract This paper describes a new canine segmental spinal fusion model for the comparison of bone‐grafting materials. The test sites in the model are three separate posterior interfacet‐interlaminar fusion sites in the lumbar spine (L1‐2, L3‐4, and L5‐6). The outcome was assessed by scoring of

Evaluation of the shedding potential of
✍ K. De Wael; L. Lepot; K. Lunstroot; F. Gason 📂 Article 📅 2010 🏛 Elsevier Science 🌐 English ⚖ 576 KB

A practical method is proposed to assess the shedding potential of textile materials. The evaluation of the sheddability is based on the use of adhesive tapes and on comparison, using three different sheddability scales for cotton, wool and fine man-made fibres.

Evaluation of thrombogenic potential of
✍ Patricia S. Wolfe; Parthasarathy Madurantakam; Koyal Garg; Scott A. Sell; Matthe 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 465 KB

## Abstract The purpose of this study was to quantify the acute expression of tissue factor (TF) by monocytes on interaction with electrospun bioresorbable constructs. A minimal expression of TF will demonstrate the potential for scaffolds to be used as a vascular graft without enhanced risk of fai

Clinical evaluations of OSTEON® as a new
✍ Young-Kyun Kim; Pil-Young Yun; Sung-Chul Lim; Su-Gwan Kim; Hyo-Jung Lee; Joo L. 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 402 KB

## Abstract ## Purpose: The objective of this study was to clinically evaluate the use of OSTEON® as a sinus graft material and to measure the effect of healing at 4 and 6 months after surgery. ## Materials and Methods: After sinus graft using OSTEON® in 17 patients, bone specimens were collecte