## Abstract This study focused on the degradation properties of gelatin microparticles incorporated in calcium phosphate (CaP) cement and the subsequent effect of these composites on bone formation. Positively charged alkaline gelatin (type A) microparticles or negatively charged acidic gelatin (ty
Evaluation of the biocompatibility of calcium phosphate cement/PLGA microparticle composites
✍ Scribed by Dennis P. Link; Juliette van den Dolder; Jeroen J. J. P. van den Beucken; Vincent M. Cuijpers; Joop G. C. Wolke; Antonios G. Mikos; John A. Jansen
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 518 KB
- Volume
- 87A
- Category
- Article
- ISSN
- 1549-3296
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
In this study, the biocompatibility of a calcium phosphate (CaP) cement incorporating poly (D,L‐lactic‐co‐glycolic acid) (PLGA) microparticles was evaluated in a subcutaneous implantation model in rats. Short‐term biocompatibility was assessed using pure CaP discs and CaP discs incorporating PLGA microparticles (20% w/w) with and without preincubation in water. Long‐term biocompatibility was assessed using CaP discs incorporating varying amounts (5, 10, or 20% w/w) and diameter sizes (small, 0–50 μm; medium, 51–100 μm, or large, 101–200 μm) of PLGA microparticles. The short‐term biocompatibility results showed a mild tissue response for all implant formulations, irrespective of disc preincubation, during the early implantation periods up to 12 days. Quantitative histological evaluation revealed that the different implant formulations induced the formation of similar fibrous tissue capsules and interfaces. The results concerning long‐term biocompatibility showed that all implants were surrounded by a thin connective tissue capsule (<10 layers of fibroblasts). Additionally, no significant differences in capsule and interface scores were observed between the different implant formulations. The implants containing 20% PLGA with medium‐ and large‐sized microparticles showed fibrous tissue ingrowth throughout the implants, indicating PLGA degradation and interconnectivity of the pores. The results demonstrate that CaP/PLGA composites evoke a minimal inflammatory response. The implants containing 20% PLGA with medium‐ and large‐sized microparticles showed fibrous tissue ingrowth after 12‐ and 24‐weeks indicating PLGA degradation and interconnectivity of the pores. Therefore, CaP/PLGA composites can be regarded as biocompatible biomaterials with potential for bone tissue engineering and advantageous possibilities of the microparticles regarding material porosity. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2008
📜 SIMILAR VOLUMES
## Abstract Injectable calcium phosphate (Ca‐P) cement materials exhibit favorable osteocompatible behavior but are resorbed slowly because of a lack of a bone ingrowth–enabling macroporosity. In this study, poly(DL‐lactic‐__co__‐glycolic acid) (PLGA) microparticles (average size 66 ± 25 μm) were i
## Abstract The aim of the current study was to evaluate the effect of a calcium phosphate material equipped with poly (lactic‐__co__‐glycolic acid) microspheres for pulp capping, and to measure the dentin bridge formation, when using various concentrations of transforming growth factor (TGF) β1. P
## Abstract Calcium phosphate cement (CPC) is a widely used bone substitute in the clinic; however, the low strength of CPC limits its utilization. In this study, we investigated mechanical influences of chitosan fiber combined with gelatin on CPC, and examined the biocompatibility of the new compo
## Abstract Development of macroporosity during setting would allow fast bone ingrowth and good osteointegration of the implant. The interconnected macropores could be created in calcium phosphate cements (CPCs) through the addition of an effervescent porogen mixture to the component of the cements