Evaluation of stationary phases and gas chromatographic detectors for determination of amines in water
✍ Scribed by Beatriz Jurado-Sánchez; Evaristo Ballesteros; Mercedes Gallego
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 194 KB
- Volume
- 33
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
For the first time, a systematic overview deals with the advantages and disadvantages of several stationary phases (polar and non‐polar) and gas chromatographic detectors (flame ionization detector, nitrogen–phosphorus detector and MS) for the determination of 27 amines (aliphatic and aromatic amines and N‐nitrosamines) in water samples. To increase sensitivity (250 mL of sample was eluted with 150 μL of solvent) and matrix elimination, an automatic SPE system was employed prior to GC determination. The best results in terms of resolution and retention times were achieved using a column coated with 5% phenyl‐dimethylpolysiloxane (DB‐5). Capacity factor (k) values for the 27 amines increased with the rise in the polarity of the stationary phase, ranging from 3.0–27.7 and 2.2–14.4 for polar (polyethylene glycol) and non‐polar (DB‐5) columns, respectively. The detection limits of the method were 0.9–9 μg/L for flame ionization detector, 8–95 ng/L for nitrogen–phosphorus detector and 0.2–6.3 ng/L for MS. The precision was similar for the three detectors (RSD, 3.7–6.0%). The GC‐MS method was applied with a high degree of accuracy and precision to determine amines in real samples including tap, river, pond, well, swimming pool and wastewaters.
📜 SIMILAR VOLUMES
Cyclic organosiloxanes were chemically bonded to silica gels and evaluated for possible use in microcolumn gas chromatography of light hydrocarbons in extraterrestrial atmospheres. DRIFT and solid state NMR spectroscopic studies confirmed the bonding of the siloxanes onto the silica surface. The sur
## Abstract In the present contribution, the performance of a number of commercially available selective and universal detectors that can be used in the analysis of sulfur components in natural gas is evaluated in terms of sensitivity, selectivity, reproducibility, quenching effect, stability, and
## Abstract In the present work, a GC method with nitrogen–phosphorus detection (NPD) was developed for the simultaneous determination of eight organophosphorus pesticide (OPP) residues (__i.e__., ethoprofos, diazinon, chlorpyrifos‐methyl, fenitrothion, malathion, chlorpyrifos, fenamiphos, and bupr
An extensive study of the behavior of three chiral stationary phases (CSP) used in liquid chromatography (LC) is presented for the stereoselective determination of methadone. The following chromatographic columns were selected: a cellulose, Chiralcel OJ; a modified cyclodextrin, Cyclobond I 2000 RSP