Examination of the Northridge fractured connections has revealed that the material as well as the manufacturing parameters associated with the fracture behaviour of these connections were largely random. This in turn implies that the fracture resistance of these connections was also random. With the
Evaluation of pre-Northridge steel moment-resisting frame joints
β Scribed by Whittaker, Andrew ;Gilani, Amir ;Bertero, Vitelmo
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 426 KB
- Volume
- 7
- Category
- Article
- ISSN
- 1062-8002
No coin nor oath required. For personal study only.
β¦ Synopsis
The 1994 Northridge earthquake caused widespread and unexpected damage to steel moment-resisting joints and connections. Shortly following the earthquake, the Federal Emergency Management Agency funded a series of full-scale tests of steel moment-resisting joints and connections to characterize the behavior of pre-earthquake connections and to evaluate the efficacy of a selected number of repair schemes. Twelve pre-earthquake connections were tested. Three of the twelve connections were tested by the authors to failure, and then repaired and re-tested. The response of the pre-earthquake connections was highly variable and uniformly poor. Premature fractures were observed in all twelve connections, and the types of fractures were similar to those observed in the field following the earthquake. The mean beam plastic rotation was 0.005 rad: one-sixth of the target value of 0.03 rad. The response of those moment-resisting connections that were repaired by replacing fractured weld and parent metal with toughness-rated weld filler metal was also poor. On the basis of the studies described in the paper, the rotation capacity of large-size moment-resisting connections built prior to the Northridge earthquake is smaller than the target values established following the earthquake; rehabilitation of earthquake-damaged moment-resisting connections by re-welding only will likely be ineffective; beam-column panel zones should be designed to remain elastic for the forces associated with plastic hinging in the beams; design equations for continuity plates should be revised; and design checks for flange compactness should be based on expected rather than nominal material properties.
π SIMILAR VOLUMES
Fires following earthquakes are considered one major threat in seismic regions. In fact, according to modern seismic codes, ordinary structures are designed to suffer damage to some extent during strong earthquakes, exploiting the structure own ductility to avoid collapse and safeguard human lives.
This study introduced and evaluated two stability coefficients that can be used to quantify the P-β effect during elastic and inelastic lateral displacement of regular steel moment resisting frames (SMRF). The first coefficient, applicable during elastic lateral displacement, was developed through a
## Abstract This study focuses on the seismic performance of Ordinary MomentβResisting Concrete Frames (OMRCF) designed only for gravity loads. For this purpose, a 3βstory OMRCF was designed in compliance with the minimum design requirements in the American Concrete Institute Building Code ACI 318