## Abstract Musculoskeletal modeling and optimization theory are often used to determine muscle forces in vivo. However, convincing quantitative evaluation of these predictions has been limited to date. The present study evaluated model predictions of knee muscle forces during walking using in vivo
Evaluation of muscle force prediction models of the lumbar trunk using surface electromyography
β Scribed by Dr. Richard E. Hughes; Don B. Chaffin; Steven A. Lavender; Gunnar B. J. Andersson
- Publisher
- Elsevier Science
- Year
- 1994
- Tongue
- English
- Weight
- 836 KB
- Volume
- 12
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Optimizationβbased models for prediction of muscle forces in the lumbar region of the torso are used to estimate the forces acting on spinal motion segments, especially for asymmetric tasks. The objectives of this study were to determine (a) which of four torso model formulations best predicted the electromyographic data, (b) the difference in muscular contribution to spinal compression force for the four models, and (c) the effect of using the lowest possible muscle stress bound in the model formulation. An approach for the investigation of competing optimization model formulations was developed and was illustrated with electromyographic data from static asymmetric loading conditions. This method is based on (a) the choice of experimental conditions in which models predict decidedly different muscle forces, and (b) the ability to ensure that the experimental conditions are such that the minimum number of assumptions about the forceβelectromyogram relationship must be made in order to choose between competing model predictions. Of the four models analyzed, only the formulation with an objective function that was the sum of cubed muscle stresses predicted the electromyographic data acceptably. The muscular contribution to spinal compression force predicted by these models differed by as much as 160% for some experimental conditions. The use of the lowest possible muscle stress bound does not appear to predict muscle forces that are in agreement with electromyographic data.
π SIMILAR VOLUMES
A three-dimensional stochastic mathematical muscle model of the knee joint has been developed and applied to a study in which the influence of both mechanical and physiological factors were examined in relation to the prediction of muscular forces about the joint. The model includes a representation
## Abstract In previous work we developed and validated a mathematical model that predicted force output from skeletal muscles subjected to sixβpulse stimulation trains under isometric condition. The current study investigated the model's ability to predict force responses to longer stimulation tra
Growth of the fetal abdomen has been reexamined in a longitudinal study of 32 normally growing fetuses using the abdominal profile area (AA) and the Rossavik growth model. The growth of the fetal abdomen was compared to that of the fetal head. In early pregnancy the growth rate was higher for the f