𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Evaluation of intraneural ganglion cysts using three-dimensional fast spin echo-cube

✍ Scribed by Kameron R. Shahid; Robert J. Spinner; John A. Skinner; Joel P. Felmlee; Jeffrey R. Bond; David W. Stanley; Kimberly K. Amrami


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
235 KB
Volume
32
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose:

To compare conventional two‐dimensional fast spin echo (FSE) MRI sequences with a three‐dimensional FSE extended echo train acquisition method, known as Cube, in the evaluation of intraneural ganglion cysts. Also, to demonstrate that Cube enables the consistent identification and thorough characterization of the cystic joint connection, and therefore improves patient care by superior preoperative planning.

Materials and Methods:

Six patients with intraneural ganglia in the knee region (five involving the peroneal and one the tibial nerve) were evaluated using both conventional FSE MR sequences and the Cube sequence. Studies were interpreted by the consensus of three board certified musculoskeletal radiologists and one peripheral nerve neurosurgeon. Surgical correlation was available in five of the six cases.

Results:

Both imaging methods demonstrated the cysts and at least part of their joint connections after variable amount of postprocessing. Cube proved superior to conventional imaging in its ability to acquire isotropic data that could easily be reconstructed in any plane and its ability to resolve fine anatomical details.

Conclusion:

Cube is a new MR pulse sequence that enables the consistent identification of the intraneural ganglion cyst joint connection. We believe that improved visualization and characterization of the entire cyst will improve patient outcomes by facilitating more accurate surgical intervention. J. Magn. Reson. Imaging 2010;32:714–718. © 2010 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Imaging of the wrist at 1.5 tesla using
✍ Kathryn J. Stevens; Charles G. Wallace; Weitian Chen; Jarrett K. Rosenberg; Garr 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 450 KB

## Abstract ## Purpose: To compare three‐dimensional fast spin echo Cube (3D‐FSE‐Cube) with conventional 2D‐FSE in MR imaging of the wrist. ## Materials and Methods: The wrists of 10 volunteers were imaged in a 1.5 Tesla MRI scanner using an eight‐channel wrist coil. The 3D‐FSE‐Cube images were

Determination of gradient magnetic field
✍ Frank G. Shellock; Mokhtar Ziarati; Dennis Atkinson; Dar-Yeong Chen 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 488 KB

The purpose of this study was to assess gradient magnetic-field-induced acoustic noise levels associated with the use of echo planar imaging (EPI) and three-dimensional fast spin echo (3D-FSE) pulse sequences. Acoustic noise measurements were obtained from two different high field-strength MR system

Unenhanced ECG-gated fast spin-echo MR d
✍ Satoru Morita; Shinya Kojima; Masami Hirata; Masaru Suzuki; Kazufumi Suzuki; Ai 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 423 KB

## Abstract ## Purpose: To compare the image qualities of unenhanced electrocardiographically (ECG)‐gated fast spin‐echo magnetic resonance digital subtraction angiography (MRDSA) using a short echo‐spacing three‐dimensional (3D) sequence, known as sampling perfection with application‐optimized co

Pre- and postprandial alterations of por
✍ Toshinobu Tsukuda; Katsuyoshi Ito; Shinji Koike; Katsumi Sasaki; Ayame Shimizu; 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 350 KB

## Abstract ## Purpose To evaluate the influence of food intake on portal flow using unenhanced magnetic resonance imaging (MRI). ## Materials and Methods The study population included 29 healthy subjects. A selective inversion recovery tagging pulse was used on the superior mesenteric vein (SMV