## Abstract ## Purpose To investigate the application of time‐resolved vastly undersampled isotropic projection reconstruction (VIPR) in contrast‐enhanced magnetic resonance angiography of the distal extremity (single station), and peripheral run‐off vasculature in the abdomen, thigh, and calf (th
Evaluation of ganglion cysts using vastly undersampled isotropic projection reconstruction (VIPR)
✍ Scribed by Kimberly K. Amrami; Nicholas M. Desy; David W. Stanley; John A. Skinner; Joel P. Felmlee; Andrew V. Barger; Walter F. Block; Robert J. Spinner
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 546 KB
- Volume
- 26
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
For some atypical para‐articular ganglia, the presence of a joint connection is highly controversial. The proper preoperative diagnosis and identification of this joint connection for ganglion cysts is important for patient treatment and outcome. MRI is the imaging modality of choice when evaluating such lesions, but the detection of subtle joint connections remains difficult with conventional MR protocols. We investigated the utility of a steady‐state free‐precession acquisition with isotropic high resolution using the vastly undersampled isotropic projection reconstruction (VIPR) pulse sequence to determine if joint connections for ganglion cysts could be seen more effectively, using the knee region as a model. We evaluated four patients: two with peroneal intraneural ganglion cysts, one with adventitial cystic disease of the popliteal artery, and one patient with a more typical extraneural (intramuscular) cyst. Both conventional MR and VIPR techniques were used. In our clinical experience, we found VIPR to be superior to conventional MR techniques in detecting and depicting joint connections in typical and atypical ganglion cysts around the knee. J. Magn. Reson. Imaging 2007. © 2007 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To determine the feasibility of the vastly undersampled isotropic projection reconstruction steady‐state free precession (VIPR‐SSFP) sequence for evaluating the articular cartilage of the knee joint. ## Materials and Methods A magnetic resonance (MR) examination of the kne
## Abstract ## Purpose To evaluate the feasibility of improving 3.0T steady‐state free precession (SSFP) whole‐heart coronary magnetic resonance angiography (MRA) using short‐TR (repetition time) VIPR (vastly undersampled isotropic projection reconstruction). ## Materials and Methods SSFP is hig