𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Evaluation of frog gastric mucous secretion by 7T magnetic resonance imaging

✍ Scribed by Andrea Sbarbati; Françoise Leclercq; Carlo Zancanaro; Uliano Guerrini; Kostas Antonakis; Francesco Osculati


Publisher
John Wiley and Sons
Year
1996
Tongue
English
Weight
573 KB
Volume
6
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

This work describes a new method to evaluate the action of drugs on gastric mucus secretion by 7 T MRI. A polyethylene probe was inserted into the stomach of frogs, a water washing cycle was performed, air was inflated into the stomach, and the probe was removed. Drugs were administered topically by mixing them with the water used for stomach washing, and a series of images was collected. In untreated animals, a mucous layer emitting a high intensity signal covered the gastric mucosa. Atropine administration strongly reduced the mucous layer thickness. After pilocarpine administration, MRI images showed that the mucous layer was thicker than in controls. After metacholine administration, the thickness of the mucous layer was increased in comparison with both controls and pilocarpine‐treated animals, in accord with the expected drug‐induced increase of mucous secretion. Quantitative analysis of the mucous layer thickness on MRI images confirmed the above findings. In conclusion, these results indicate that MRI at 7 T is a sensitive in vivo screening test to evaluate the effect of drugs on gastric mucus secretion in absence of surgical manipulation, thereby enabling morphofunctional studies that cannot be performed by conventional methods.


📜 SIMILAR VOLUMES


Morphologic and functional evaluation of
✍ Dominique Didier; Osman Ratib; Maurice Beghetti; Ingrid Oberhaensli; Beat Friedl 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 985 KB

Magnetic resonance imaging (MRI) has evolved sufficiently to be recognized as a useful complementary noninvasive method to echocardiography in the evaluation of congenital heart disease (CHD). In some cases, MRI is superior to other imaging modalities, particularly in the evaluation of thoracic aort

Evaluation of neoadjuvant chemotherapeut
✍ Dana C. Abraham; Ronald C. Jones; Stephen E. Jones; J. Harold Cheek; George N. P 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 938 KB

## BACKGROUND. The implementation of new treatment protocols for locally advanced breast cancer is currently limited by inaccurate evaluation of response to neoadjuvant chemotherapy. A recently developed dedicated breast magnetic resonance imaging (MRI) method (RODEO MRI) was evaluated as a tool f

An evaluation of the integrity of the bl
✍ Hassan Farghali; Donald S. Williams; Elena Simplaceanu; Chien Ho; David H. Van T 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 421 KB

## Abstract This present investigation was initiated to noninvasively evaluate the usefulness of intravenous gadopentetate dimeglumine (Gd‐PTDM) ‐enhanced magnetic resonance imaging (MRI) in assessing the integrity of the blood‐testis barrier (BTB). The intensity of different image slices was measu

Hemodynamic evaluation of the peripheral
✍ Christian J. Kellenberger; Christopher K. Macgowan; Kevin S. Roman; Fahad Al-Hab 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 328 KB 👁 1 views

## Abstract ## Purpose To describe the normal flow patterns in peripheral pulmonary vessels with phase‐contrast (PC) magnetic resonance imaging (MRI). ## Materials and Methods Twelve healthy adults (age = 33 ± 7 years) underwent cine PC MRI of the segmental and central pulmonary arteries and vei