Evaluation of Fasting Plasma Glucose as a Screening Test for Diabetes Mellitus in Singaporean Adults

✍ Scribed by Lee, C.H.; Fook-Chong, S.


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
131 KB
Volume
14
Category
Article
ISSN
0742-3071

No coin nor oath required. For personal study only.

✦ Synopsis


To assess the performance of different cutoff points for fasting plasma glucose (FPG) including the World Health Organization (WHO) cutoff of FPG Ρƒ7.8 mmol l -1 for the screening of diabetes mellitus, data from oral glucose tolerance tests done on 865 Singaporean adults over a 4-year period were analysed. The relationship between FPG and 2 h post-load plasma glucose (2H-PG) was determined using regression analysis and receiver operating characteristic (ROC) analysis. Out of 220 subjects with 2H-PG exceeding 11.1 mmol l -1 , only 90 had FPG exceeding 7.8 mmol l -1 , yielding a sensitivity of only 40.9 %. The relationship between FPG and 2H-PG was non-linear and conformed to a cubic equation [FPG = 3.0890 + 0.0272 (2H-PG) 2 -0.0006 (2H-PG) 3 ]. ROC analysis determined an FPG of 5.7 mmol l -1 to yield optimal sensitivity and specificity. Although in the clinical setting, FPG is an extremely useful screening test for diabetes, it is clear, as has been shown in other studies, that the traditional WHO criterion of FPG Ρƒ7.8 mmol l -1 is highly insensitive for detecting diabetes. Lower FPG cutoffs achieve greater sensitivity albeit at the expense of reduced specificity. Although ROC analysis in this population determines the optimally sensitive and specific FPG cutoff to be 5.7 mmol l -1 , we suggest that the FPG cutoff should be adjusted to 7.0 mmol l -1 for preservation of specificity. KEY WORDS Oral glucose tolerance test Fasting plasma glucose 2-hour post-load plasma glucose Receiver operating characteristics Singapore was an often asymptomatic condition with an onset as Patients and methods Abbreviations: OGTT oral glucose tolerance test, FPG fasting plasma glucose, 2H-PG 2 hour post-load plasma glucose, ROC receiver operating characteristics, WHO World Health Organization, CV We examined 865 OGTTs performed over a 4-year period coefficient of variation


πŸ“œ SIMILAR VOLUMES


Letter: Fasting plasma glucose as a scre
✍ Wiener, K πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 95 KB πŸ‘ 1 views

Figure 1. Agreement blood glucose values measured by Hemocue after adjustment 2329-2332. to plasma values (H\*) and Beckman analyser (B) 9

The relative merits of haemoglobin A1c a
✍ Wiener, K.; Roberts, N.B. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 119 KB πŸ‘ 2 views

HbA 1c was measured by high-performance ion-exchange chromatography in 401 nonpregnant patients undergoing oral glucose tolerance tests (OGTT). All those with HbA 1c ΟΎ6.2 % (reference range 3.8-5.5 %) had diabetic OGTT (sensitivity 41 %, specificity 100 %). Although a fasting plasma glucose (FPG) cu