Evaluation of dual-energy X-ray absorptiometry bone mineral measurement—comparison of a single-beam and fan-beam design: The effect of osteophytic calcification on spine bone mineral density

✍ Scribed by H. Franck; M. Munz; M. Scherrer


Publisher
Springer
Year
1995
Tongue
English
Weight
408 KB
Volume
56
Category
Article
ISSN
1432-0827

No coin nor oath required. For personal study only.

✦ Synopsis


Dual energy X-ray absorptiometry (DXA) using a single-beam (SB) design is a well-established procedure for measuring bone mineral area density (BMD). Recently, fan beam (FB) techniques have become available to measure BMD. We evaluated the QDR1000 and QDR2000 densitometers with regard to precision and cross-compared values using single beam (SB) and FB techniques. To study the effect of osteoarthritic changes on bone measurement (BMC in g) and bone mineral area density (BMD in g/cm2), both parameters were measured in patients with and without osteophytic calcifications (OC) of the lumbar spine. Precision errors for BMD in vitro over 1 and 6 months using the QDR2000 were 0.4% and 0.6% for SB and 0.5% and 0.7% for the three FB modes. For QDR1000 only SB is available. Using this scan mode, the BMD difference (delta = 0.1%) in vitro between QDR1000 and QDR2000 was not significant. The short-term (same day) reproducibility of BMD in vivo was 0.85% for SB mode and 1.1% for FB scan mode (n = 33). The midterm (1 month) precision errors were 0.9% for SB and 1.5% for FB (n = 11). The spine BMD of 751 patients from our outpatient clinic and department of rheumatology was 1.7% lower with FB than with SB (0.878 +/- 0.137 versus 0.888 +/- 0.146 g/cm2). Lower (1.8%) BMD values were also found in the hip with FB compared to SB (0.805 +/- 0.111 versus 0.821 +/- 0.111 g/cm2). There was a highly significant (P < 0.00001) correlation between SB and FB on the spine (r = 0.99) and hip (r = 0.98) using the QDR2000. Correlations found QDR1000 and QDR2000 were lower on the spine (r = 0.97) and hip (r = 0.93).(ABSTRACT TRUNCATED AT 250 WORDS)


📜 SIMILAR VOLUMES


Lateral spine dual-energy X-ray absorpti
✍ H. Franck; M. Munz; M. Scherrer; H. V. Lilienfeld-Toal 📂 Article 📅 1995 🏛 Springer 🌐 English ⚖ 409 KB

Recently, fan beam (FB) designs have been made available by several manufacturers (Aloka, Hologic Lunar and Sophar) to measure lumbar spine bone mineral area density (BMD) in both an anteroposterior (AP) and a lateral projection. The present study was performed to evaluate some characteristics of a

Evaluation of periprosthetic bone using
✍ Heikki Kröger; Hannu Miettinen; Ilkka Arnala; Eila Koski; Neil Rushton; Olavi Su 📂 Article 📅 2009 🏛 American Society for Bone and Mineral Research 🌐 English ⚖ 466 KB

To assess the perioperative bone loss of femur during total hip arthroplasty (THA), periprosthetic bone mineral density (BMD) of the seven regions of interests (Gruen zones) was determined with dual-energy x-ray absorptiometry (DXA) preoperatively in both proximal femurs and postoperatively in the i