## Abstract A new generation combination test (Detect‐Plus, IAF BioChem, Montreal, Canada) based on synthetic peptides for HIV‐1, HIV‐2, HTLV‐I, and HTLV‐II was compared with three routine commercial screening assays and confirmatory assays to determine its sensitivity and specificity and to evalua
Evaluation of a new screening assay for HTLV-1 and -2 antibodies for large-scale use
✍ Scribed by Kerstin Malm; Torbjörn Kjerstadius; Sören Andersson
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 88 KB
- Volume
- 82
- Category
- Article
- ISSN
- 0146-6615
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Laboratory testing for Human T‐lymphotropic Virus type 1 and 2 (HTLV‐1 and ‐2) infections has become routine in blood transfusion, tissue transplantation and clinical diagnoses in many countries worldwide. Screening is usually based on the detection of antibodies to HTLV‐1 and/ or ‐2. The number of commercially available assays is limited, and among them, ELISA tests based on microtiter format are most commonly used. Recently, the new __r__HTLV‐I/II assay (Abbott Laboratories, Abbott Park, IL) was released; this assay was developed for an automatic large‐scale screening platform. This assay was evaluated using pre‐characterized serum panels and routine samples from the clinical laboratory. The sensitivity was 100% for HTLV‐1 and ‐2 (99/99 and 42/42, respectively, including one sample that was dually reactive, HTLV‐1 + 2). To test assay specificity, panels of blood donor sera, specimens from patients with autoimmune diseases and some viral infections were used. False‐reactive samples from previous HTLV diagnoses were also included. With these panels, the specificity was 99.4% (619/623). However, the four false‐reactive samples all belonged to the group of samples that were previously considered as false‐reactive for HTLV‐antibodies. All other samples were negative by the __r__HTLV‐I/II assay, and thus 100% specificity was obtained. The 1,412 samples tested in the clinic by this assay in routine use were all negative (100% specificity). Taken together, the overall specificity was 99.8%. The assay was sensitive, specific and appropriate for the large‐scale screening of samples for HTLV‐1/2 antibodies. J. Med. Virol. 82:1606–1611, 2010. © 2010 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Screening blood donations for human T‐lymphotropic virus types I and II (HTLV‐I/II) continues to be important in protecting the safety of blood products and controlling the global spread of these retroviruses. We have developed a fully automated, third generation chemiluminescent immuno
## Communicated by Paolo Fortina FRAXE (FMR2) is a fragile site associated with mental impairment located in Xq28, 600 kb distal to FRAXA (FMR1), the fragile X syndrome fragile site. The FRAXE mutation is an expansion of a CCG repeat that results in methylation of a nearby CpG island. FRAXE allele
A method for detection of large genomic deletions in the MSH2 and MLH1 genes based on multiplex PCR and quantitative evaluation of PCR products is presented. All 35 exons of MSH2 and MLH1 were screened simultaneously in seven PCR reactions, each of them including primers for both genes. The method i
In France, despite high risk from myocardial infarction (MO) consequent upon smoking, lack of exercise and a high-fat diet, the incidence of MI is much lower than in N. America. This 'French Paradox' has been attributed to their high consumption of red wine known to contain phenolic constituents (re
## Objectives: To develop and validate an enzyme-linked immunosorbent assay (elisa) for measurement of urinary 2,3-dinor-6-keto-prostaglandin f1 alpha (2,3d6kpgf1 alpha) using a monoclonal antibody and a horseradish peroxidase-linked antigen. ## Design and methods: Assay validation included optim