✦ Synopsis


Abstract

This investigation attempts to apply the concept of direct sketal attachment via tissue ingrowth to the attachment of femoral head prosthess to the femur. Stainless steel (316L) canine femoral head prostheses with a ceramic coated stem were implanted into the femora of dogs and their results compared to those obtained by the impaction of stainless steel prostheses and acrylic‐stabilized prostheses. The implants were tested in vivo for time periods ranging from 2 to 13 months, after which time the animals were sacrificed and the femora excised. The femora were sectioned with the implants in place and prepared for examination by light microscopy. Bone was in closer approximation to the ceramic coated implants than to the other two types of implantations. The uncoated and acrylic‐stabilized implants were usually charaterized by the presence of a relatively thick fibrous sequestering membrane.


📜 SIMILAR VOLUMES


Wear evaluation of cobalt-chromium alloy
✍ St. John, Kenneth R. ;Zardiackas, Lyle D. ;Poggie, Robert A. 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 270 KB

## Abstract Wear of the polyethylene in total joint prostheses has been a source of morbidity and early device failure, which has been extensively reported in the last 20 years. Although research continues to attempt to reduce the wear of polyethylene joint‐bearing surfaces by modifications in poly

Evaluation of a bioglass-coated Al2O3 to
✍ Griss, P. ;Greenspan, D. C. ;Heimke, G. ;Krempien, B. ;Buchinger, R. ;Hench, L. 📂 Article 📅 1976 🏛 John Wiley and Sons 🌐 English ⚖ 514 KB

## Abstract A bioglass‐coated fully dense alumina total hip was evaluated in sheep without using polymer bone “cement.” After 3 months following surgery, both the acetabular cup and femoral stem component were firmly attached to bone. Histologic and radiographic analysis of the bone–implant interfa

Cementless prosthesis of the hip joint w
✍ W. Plötz; R. Gradinger; H. Rechl; R. Ascherl; S. Wicke-Wittenius; E. Hipp 📂 Article 📅 1992 🏛 Springer 🌐 English ⚖ 849 KB

Our investigations in human specimens and animal experiments show that prostheses with a spongy metal surface can become fixed by bony ingrowth to varying degrees. After consistent clinical and radiological follow-up over 12-65 months (mean 34 months) in a prospective study of 100 consecutive patien