Abstract
Aim
For decades, monophasic square wave pulses have been used for intravesical electrical stimulation (IVES) in diagnosis and treatment of lower urinary tract dysfunction. The use of other waveforms, more preferred by patients or more effective for neural stimulation, has hardly been studied before. This study compares the effect of several waveforms and derived parameters in IVES.
Methods
IVES, performed in eight female Sprague–Dawley rats, was given for 300 sec with constant frequency (10 Hz) and current amplitude (6 mA) with unipolar square, biphasic square, asymmetric biphasic square, double square, unipolar exponential rise, biphasic exponential rise, and double‐exponential rise wavepulses with different pulse durations (2 × 5 msec, 20 msec, or 2 × 20 msec). Bladder pressure was recorded. Average current and average power were calculated.
Results
Stimulations with the different waveforms resulted in the same maximal pressure rise (all P > 0.1). The average charge was zero for biphasic waveforms. For exponential rise pulse waveforms the total injected charge was lower than that for the monophasic square pulse waveform. The average power was the highest for biphasic waveforms and the lowest for monophasic double‐exponential rise pulses waveform.
Conclusions
Charge‐balanced waveforms, which are more preferred by patients, are equally effective in evoking IVES‐induced detrusor contraction as monophasic square pulse waveforms. Thus, it can be beneficial in clinical practice to replace the monophasic square pulse waveform for IVES by charge‐balanced waveforms. Furthermore, the stimulation power and thus the requested energy can be reduced by changing the waveform. This can be important for electrical stimulation using implanted batteries. Neurourol. Urodyn. 30:169–173, 2011. © 2010 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
Intravesical electrical stimulation (IVES) is used clinically to improve bladder evacuation in patients with inadequate micturition contractions. The procedure involves field stimulation of A␦ bladder mechanoreceptor afferents resulting in a prolonged enhancement of the micturition reflex. The aim o
A model is described to study absorption kinetics of drugs in the unanesthetized rat. The surgical technique consists of a long-term isolation of an intestinal segment inside the animal. This isolated loop is used in perfusion experiments. In this model the effects of anesthesia and surgical trauma
## Abstract ErbB2 has been implicated in numerous functions, including normal and aberrant development of a variety of tissues. Although no soluble ligand has been identified for ErbB2, we have recently shown that ASGP‐2, the transmembrane subunit of the cell surface glycoprotein Muc4 (also called
The genetic epidemiologic study of coronary heart disease conducted by a group in the Donner Laboratory used survey and ad hoc sampling plans, resulting in a random and an ad hoc sample of families, respectively. These two samples were used to evaluate the ad hoe sampling plan used in that study. Fo