𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Estimation of the differential pressure at renal artery stenoses

✍ Scribed by Peter J. Yim; Juan R. Cebral; Ashley Weaver; Robert J. Lutz; Orlando Soto; G. Boudewijn C. Vasbinder; Vincent B. Ho; Peter L. Choyke


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
421 KB
Volume
51
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Atherosclerotic disease of the renal artery can lead to reduction in arterial caliber and ultimately to conditions including renovascular hypertension. Renal artery stenosis is conventionally assessed, using angiography, according to the severity of the stenosis. However, the severity of a stenosis is not a reliable indicator of functional significance, or associated differential pressure, of a stenosis. A methodology is proposed for estimation of the renal artery differential pressure (RADP) from MR imaging. Realistic computational fluid dynamics (CFD) models are constructed from MR angiography (MRA) and phase‐contrast (PC) MR. The CFD model is constructed in a semiautomated manner from the MR images using the Isosurface Deformable Model (IDM) for surface reconstruction and a Marching Front algorithm for construction of the volumetric CFD mesh. Validation of RADP estimation was performed in a realistic physical flow‐through model. Under steady flow, the CFD estimate of the differential pressure across a stenosis in the physical flow‐through model differed by an average of 5.5 mmHg from transducer measurements of the pressure differential, for differential pressures less than 60 mmHg. These results demonstrate that accurate estimates of differential pressure at stenoses may be possible based only on structural and flow images. Magn Reson Med 51:969–977, 2004. Published 2004 Wiley‐Liss, Inc.


πŸ“œ SIMILAR VOLUMES


Estimation of renal extraction fraction
✍ Yakir S. Levin; Lawrence C. Chow; Norbert J. Pelc; F. Graham Sommer; Daniel M. S πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 490 KB

## Abstract An error analysis for quantifying single kidney extraction fraction (EF) via differential __T__~1~ measurements in the renal vein (RV) and renal artery (RA) is presented. Sources of error include blood flow effects, the effect of a short repetition time (TR), and the impact of uncertain

The efficacy of using pulmonary vein wed
✍ Manatomo Toyono; Kenji Harada; Masamichi Tamura; Kenji Yasuoka; Tomomi Oyama; Go πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 105 KB πŸ‘ 3 views

## Abstract The objectives of this study were to assess the accuracy of pulmonary vein wedge pressure (PVWP) in estimating pulmonary artery pressure (PAP) in various types of congenital heart disease, including single‐ventricle physiology. The systolic, diastolic, and mean values of both PAPs and P