Estimating tissue strain from signal decorrelation using the correlation coefficient

โœ Scribed by Tomy Varghese; Jonathan Ophir


Book ID
104324598
Publisher
Elsevier Science
Year
1996
Tongue
English
Weight
638 KB
Volume
22
Category
Article
ISSN
0301-5629

No coin nor oath required. For personal study only.

โœฆ Synopsis


A simple relationship between the correlation coefficient and the applied strain, applicable only at low strains, is presented in this article. This relationship is derived for a Gaussian modulated cosine point spread function. The performance of the strain estimator is analyzed using a theoretical expression for the correlation coefficient along with simulation and experimental results. Both the theoretical and simulation results diverge from the ideal relationship between the strain and the correlation coefficient as the applied strain is increased. Simulation results illustrate that the strain estimate obtained using the correlation coefficient is a biased estimate with a large variability. Experimental results, however, illustrate that strain estimation using the 1-D correlation coefficient estimate is applicable only at high signal-to-noise ratios in the radiofrequency signal and in the absence of lateral and elevational signal decorrelation.


๐Ÿ“œ SIMILAR VOLUMES


On the use of envelope and RF signal dec
โœ S.Kaisar Alam; J. Ophir ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 665 KB

Bamber and Bush (1995) used the correlation coefficient for freehand elasticity imaging. Varghese and Ophir (1996) found it to be a biased estimator of strain with a large variability. In this study, we systematically investigate the effect of changes in various system and processing parameters on t

Saliva and serum samples were collected
Saliva and serum samples were collected from eight healthy volunteers every two hours during a 26-hour period. Melatonin concentrations were measured by radioimmunoassay after chloroform extraction using radioiodinated melatonin as a tracer. Five of the subjects had high serum melatonin levels at night (peak levels higher than 75 pg/ml); in three subjects the highest serum melatonin concentration was 20-40 pg/ml. All subjects had low levels (P <0.001, was obtained for all detectable value pairs (n= 73). The regression and correlation coefficients were almost equal for the peak values of melatonin and during the rising and descending phases of the secretion patterns. However, no significant correlation was found between low daytime salivary and serum concentrations when calculated separately. In the five high-secretors the melatonin levels in saliva reflected reliably the changes in serum, but in the three low-secretors the correlation between salivary and serum melatonin was not significant. The proportion of melatonin found in saliva decreased with increasing serum melatonin levels. Circadian rhythm parameters were estimated by single cosinor analysis. The acrophases did not differ significantly within a subject in the concomitant measurements of serum and salivary melatonin. The measurements of salivary melatonin levels seem valid for studies on melatonin rhythms, but the melatonin concentrations measured in saliva do not always consistently reflect the absolute concentrations in blood.
โœ Maija-Liisa Laakso; Tarja Porkka-Heiskanen; Aino Alila; Dag Stenberg; Gunnar Joh ๐Ÿ“‚ Article ๐Ÿ“… 1990 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 622 KB