## Abstract Psychotropic drugs have been associated with sudden deaths and the lengthening of corrected‐QT interval (QTc) on the electrocardiogram which may be a precursor of life‐threatening arrhythmias as reported with some of these drugs. The objectives of this study were to measure the frequenc
Erythromycin Prolongs the QTc Interval Among Patients with Pneumonia
✍ Scribed by Jonathan Freeman; Richard Platt
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 141 KB
- Volume
- 6
- Category
- Article
- ISSN
- 1053-8569
No coin nor oath required. For personal study only.
✦ Synopsis
Erythromycin is commonly used to treat simple community-acquired pneumonia. We measured the prolongation in QT c intervals in EKGs associated with intravenous erythromycin administration among patients hospitalized for simple pneumonia (DRGs 89 and 90). We reviewed the medical records of 50 patients who received at least 5 days of intravenous erythromycin, and found 15 with readable paired EKGs, at least one taken during the period of erythromycin administration and at least one other obtained when the patient had no erythromycin. The mean QT c interval in lead II for EKGs taken without erythromycin was 0.422 s and the average prolongation of the QT c interval associated with erythromycin administration was 0.046 s (P `0.01). The administration of erythromycin was thus associated with an increase in QT c intervals to a mean of 0.468 s, a value considered to be abnormally prolonged. We conclude that erythromycin prolongs the QT c interval among patients hospitalized with pneumonia in the same manner previously reported for healthy volunteers in an experimental setting. The magnitude of this erythromycin-induced QT c prolongation raises QT c intervals into the abnormal range. Although no patient in this small study suered an adverse eect from the QT c prolongation, the magnitude of this eect is suciently large to raise clinical concerns.
📜 SIMILAR VOLUMES
## Objective: Newborns of mothers positive for anti-ro/ssa autoantibodies may develop a series of electrocardiographic (ekg) disturbances. prolongation of the corrected qt (qtc) interval was recently reported in a significant proportion of children with maternally acquired anti-ro/ssa antibodies, w
## Abstract ## BACKGROUND: No study has assessed the ability of pneumonia severity scores to identify the risk for early intensive care unit (ICU) transfer in patients with community‐acquired pneumonia (CAP) admitted to general wards (GW). We aimed to compare the ability of CURB‐65 (confusion, ure