๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Errors in T2 estimation using multislice multiple-echo imaging

โœ Scribed by A. P. Crawley; R. M. Henkelman


Publisher
John Wiley and Sons
Year
1987
Tongue
English
Weight
801 KB
Volume
4
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

โœฆ Synopsis


Accurate T2 images calculated from multiple-echo sequences are difficult to obtain over a number of contiguous slices due to the presence of unwanted echoes that are generated at the slice edges. This problem is similar to problems encountered in single-slice imaging in the presence of rf pulse imperfections. In this paper, we use computer simulations to show that all unwanted echoes can be eliminated by defocusing them using additions to the slice-selection gradients. Accurate T2 images may then be calculated from the remaining echoes. We also present a method of experimentally displaying the slice shapes of unwanted echoes generated by a multislice imaging sequence.


๐Ÿ“œ SIMILAR VOLUMES


T2 maximum likelihood estimation from mu
โœ Jean-Marie Bonny; Michel Zanca; Jean-Yves Boire; Annie Veyre ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 610 KB

## Abstract An optimal maximum likelihood (ML) method is described for an unbiased estimation of monoexponential __T__~2~ from magnitude spinโ€echo images. The algorithm is based on a Gaussian assumption of noise distribution. The validity of this assumption was checked by a statistical __x__^2^ tes

Errors in the measurements of T2 using m
โœ S. Majumdar; S. C. Orphanoudakis; A. Gmitro; M. O'Donnell; J. C. Gore ๐Ÿ“‚ Article ๐Ÿ“… 1986 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 547 KB

The accurate estimation of the spin-spin relaxation time T2 is an important goal in magnetic resonance imaging particularly because it can be used for quantitative tissue characterization. The spin-spin relaxation time T2 may be estimated using multiecho pulse sequences, but the accuracy of the esti

Using adiabatic inversion pulses for lon
โœ Peder E. Z. Larson; Steven M. Conolly; John M. Pauly; Dwight G. Nishimura ๐Ÿ“‚ Article ๐Ÿ“… 2007 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 444 KB

## Abstract Ultrashort echo time (UTE) imaging is a technique that can visualize tissues with subโ€millisecond __T__~2~ values that have little or no signal in conventional MRI techniques. The shortโ€__T__~2~ tissues, which include tendons, menisci, calcifications, and cortical bone, are often obscur

An estimation and correction scheme for
โœ S. Majumdar; A. Gmitro; S. C. Orphanoudakis; D. Reddy; J. C. Gore ๐Ÿ“‚ Article ๐Ÿ“… 1987 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 839 KB

Multiecho sequences are widely used in MRI because they are an efficient means of acquiring data and they can be used to quantitatively estimate Tz. However, the uniformity of each image and the accuracy of each T2 estimate may be corrupted by several instrumental factors such as rfpulse imperfectio

Diffusion-weighted imaging of human caro
โœ Seong-Eun Kim; Eun-Kee Jeong; Xian-Feng Shi; Glen Morrell; Gerald S. Treiman; De ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 855 KB

## Abstract ## Purpose: To determine if 2D singleโ€shot interleaved multislice inner volume diffusionโ€weighted echo planar imaging (ssโ€IMIVโ€DWEPI) can be used to obtain quantitative diffusion measurements that can assist in the identification of plaque components in the cervical carotid artery. ##